The Whole Toolkit Tested in Carotid Artery Stenting

This study sought to randomly compare the double-layer Roadsaver stent (Terumo) with the single-layer Carotid Wallstent device (Boston) in association with either distal filter-like embolic protection device FilterWire (Boston) or proximal protection device Mo.Ma (Medtronic) in patients with lipid-rich carotid plaques.

Por primera vez un estudio confirma que las pantallas de protección plomadas resguardan de la radiación a todo el personal de la sala de cateterismos

This is a very interesting work because there are no head-to-head simultaneous comparisons between these stent types and these brain protection systems: we only had physiopathological speculation.

A total of 104 consecutive patients were randomized to carotid artery stenting with FilterWire + Roadsaver stent (group 1, n = 27), FilterWire + Wallstent (group 2, n = 25), Mo.Ma + Roadsaver stent (group 3, n = 27), or Mo.Ma + Wallstent (group 4, n = 25).

The primary endpoint was the number of microembolic signals on transcranial Doppler in each procedural step: target vessel access; lesion wiring; pre-dilation; stent crossing; stent deployment; post-dilation, and device retrieval.


Read also: Crest-2 Registry: Carotid PCI Presents Low Rates of Death and Stroke.


The Mo.Ma was significantly superior to the FilterWire device in the reduction of microembolic signals (p < 0.0001) during lesion crossing, stent crossing, stent deployment, and post-dilation.

The Roadsaver was significantly superior to the Wallstent device (p = 0.016) during stent deployment and device retrieval. It also reduced the number of spontaneous microembolic signals (29% of patients).

The combination of proximal protection device Mo.Ma and double-layer stent Roadsaver was superior (p = 0.043) to all other combinations.


Read also: New Device for More Protection in Carotid Artery Stenting.


These were the differences found regarding microembolic signals on transcranial Doppler, but there were no clinical differences.

After stenting, peak systolic velocity decreased in all patients. At 6 months, only one patient experienced restenosis.

Conclusion

In patients with high-risk, lipid-rich carotid plaque, angioplasty combining proximal protection device Mo.Ma and double-layer stent Roadsaver resulted in the lowest number of microembolic signals on transcranial Doppler.

Original title: Carotid Wallstent Versus Roadsaver Stent and Distal Versus Proximal Protection on Cerebral Microembolization During Carotid Artery Stenting.

Reference: Piero Montorsi et al. J Am Coll Cardiol Intv 2020;13:403–14.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Transcatheter Pulmonary Valve Implantation with a Self-Expanding Valve: Outcomes at 3 Years

Pulmonary regurgitation (PR) is a common condition in patients who have undergone surgical repair of Tetralogy of Fallot or other pathologies involving the right...

RACE Trial: Effect of Balloon Pulmonary Angioplasty and Riociguat on Right Ventricular Afterload and Function in Chronic Thromboembolic Pulmonary Hypertension

Even though pulmonary endarterectomy is the treatment of choice for chronic thromboembolic pulmonary hypertension (CTEPH), up to 40% of patients are not candidates because...

ACC-2025 Congress Second Day Key Studies

BHF PROTECT-TAVI (Kharbanda RK, Kennedy J, Dodd M, et al.)The largest randomized  trial carried out across 33 UK centers between 2020 and 2024, assessing...

ACC 2025 | API-CAT: Reduced vs. Full Dose Extended Anticoagulation in Patients with Cancer Related VTE

The risk of cancer related recurrent venous thromboembolism (VTE) will drop over time, while bleeding risk will persist. At present, it is recommended we...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Pretreatment with DAPT in Acute Coronary Syndrome: An Ongoing Debate?

In acute coronary syndrome (ACS) dual antiplatelet therapy (DAPT) has become a fundamental pillar after percutaneous coronary intervention (PCI), preventing stent thrombosis and acute...

Measuring Post-TAVI Gradients and Their Implications: Are Invasive and Echocardiographic Assessments Comparable?

Transcatheter aortic valve implantation (TAVI) is considered the treatment of choice for a significant proportion of patients with symptomatic aortic stenosis. Outcomes have improved...

Another Blow for Intra-Aortic Balloon Pumo Counterpulsation? Randomized Study on Its Use in Chronic Heart Failure Progressing to Cardiogenic Shock

Cardiogenic shock (CS) remains a condition with extremely high mortality (around 50%). While most therapies for this pathology have been studied in CS secondary...