Promising Results of Transcatheter Mitral Valve Replacement in Bioprosthesis Failure

Failure of a mitral bioprosthesis always poses a challenge regarding decision-making, especially when dealing with elderly patients with multiple risk factors. The scenario is worsened by the high risk associated with a new sternotomy and the significant impact of undergoing new surgery.

Reemplazo Mitral Transcatéter en Fallas de Bioprótesis

Transcatheter mitral valve-in-valve (TMViV) replacement is emerging as a valid strategy in the aforementioned cases of bioprosthesis failure. However, unfortunately, we currently lack comprehensive analyses and large-scale randomized studies.

In this study, researchers conducted an analysis of 20 consecutive symptomatic patients who underwent TMViV replacement due to bioprosthesis failure.

Subjects with mitral annulus, annular calcification in the surgical bioprosthesis, or a transapical percutaneous valve were excluded.

The average age was 64 years, and 12 patients were women. More than half of the patients had diabetes, preserved renal function, an STS Score of 8.1%, and a EuroSCORE II of 9.2%.

Read also: Clopidogrel Monotherapy Beyond 12 months: Long Term Analysis of the STOPDAPT-2.

Before the procedure, ejection fraction was 44%, with a mean gradient of 13 mmHg. Bioprosthesis failure presented as stenosis with regurgitation in 12 patients, stenosis alone in 5 cases, and regurgitation alone in 2.

The procedure was successful in all patients, with no mortality, infarcton, or stroke. Three patients experienced major bleeding, one required automatic implantable cardioverter defibrillator (AICD), another needed dialysis, and the average hospital stay was 7 days.

Mortality at 30 days and one year was 1 patient and 2 patients, respectively.

Read also: Use of Apixaban and Post TAVR Valve Thrombosis.

After one year of follow-up, all patients were in functional classes I-II, with a gradient of 6 mmHg and an ejection fraction of 44%. All continued anticoagulation.

Conclusion

TMViM replacement with Meril Myval can be performed safely, with high technical success and low mortality at 30 days and one year.

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Clinical Outcomes Following Transcatheter Mitral Valve-in-Valve Replacement Using a Meril Myval Transcatheter Heart Valve.

Reference: Mullasari Ajit Sankardas, et al. Heart, Lung and Circulation (2023) , article in press.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...

Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study

The expansion of transcatheter aortic valve implantation (TAVI) toward younger and lower-risk patients has increased the relevance of post-procedural coronary access. In this context,...

TEER plus optimal medical therapy versus medical therapy alone in functional mitral regurgitation

Mitral regurgitation (MR) is a highly prevalent valvular heart disease that, in advanced stages and when left untreated, is associated with reduced quality of...

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Duration of Smoking Cessation and Risk of Amputation After Revascularization in Critical Limb Ischemia

Critical limb ischemia (CLI) is associated with high rates of amputation and mortality. Although smoking cessation improves outcomes after revascularization, the impact of the...

Conservative management of endoleaks in complex aortic endografts under CT angiography follow-up

Endoleaks remain one of the leading causes of reintervention after endovascular repair of complex aortic aneurysms using fenestrated and/or branched endografts (F/B-EVAR). Traditionally, type...

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...