ACC 2024 | SMART Trial: Self-Expanding or Balloon-Expandable TAVR in Patients with Small Aortic Annulus

Patients with severe aortic stenosis and a small aortic annulus face an increased risk of deteriorated valvular hemodynamic performance and adverse cardiovascular clinical outcomes after undergoing transcatheter aortic valve replacement (TAVR).

ACC 2024

This study, a prospective multicenter randomized trial, aimed to compare the efficacy and safety of two types of valves: the supra-annular self-expanding EVOLUT (SEV) and intra-annular balloon-expandable SAPIEN (BEV).

Patients with symptomatic severe aortic stenosis and an aortic valve annulus area of 430 mm2 or less were randomized 1:1 to undergo TAVR with a supra-annular self-expanding valve or a balloon-expandable valve. The primary endpoints, assessed over 12 months, were a composite of death, disabling stroke, or rehospitalization for heart failure (evaluated for non-inferiority) and a composite endpoint measuring bioprosthetic valve dysfunction (evaluated for superiority).

The study included a total of 716 patients, with a mean age of 80 years; most subjects were women (87%), and the average STS score was 3.3%. The Kaplan-Meier estimate of the percentage of patients experiencing the composite events of death, disabling stroke, or rehospitalization for heart failure over 12 months was 9.4% with the self-expanding valve and 10.6% with the balloon-expandable valve (a difference of -1.2 percentage points; 90% confidence interval [CI] -4.9 to 2.5; P < 0.001 for non-inferiority).

Read also: ACC 2024 | PREVENT Study.

The Kaplan-Meier estimate of the percentage of patients with bioprosthetic valve dysfunction over 12 months was 9.4% with the self-expanding valve and 41.6% with the balloon-expandable valve (a difference of -32.2 percentage points; 95% CI -38.7 to -25.6; P < 0.001 for superiority).

The mean aortic valve gradient at 12 months was 7.7 mm Hg with the self-expanding valve and 15.7 mm Hg with the balloon-expandable valve. The corresponding values for additional secondary endpoints over 12 months were, respectively, as follows: mean effective orifice area, 1.99 cm2 and 1.50 cm2; percentage of patients with hemodynamic structural valve dysfunction, 3.5% and 32.8%; and percentage of women with bioprosthetic valve dysfunction, 10.2% and 43.3% (P < 0.001 in all cases). The main safety endpoints appeared to be similar in both groups.

Conclusions

In conclusion, among patients with severe aortic stenosis and a small aortic annulus undergoing TAVR, the supra-annular self-expanding valve was non-inferior to the balloon-expandable valve in terms of clinical outcomes and superior in terms of bioprosthetic valve dysfunction over 12 months.

Dr. Andrés Rodríguez.
Member of the editorial board of SOLACI.org.

Original Title: Self-Expanding or Balloon-Expandable TAVR in Patients with a Small Aortic Annulus SMART trial.

Reference: Howard C. Herrmann, M.D et al.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

TCT 2024 | TRISCEND II

This randomized study included 400 patients; 267 were treated with EVOQUE valve and 133 with optimal medical treatment (OMT). After one-year follow-up, there were no...

TCT 2024 – ACCESS-TAVI: Comparing Percutaneous Access Closure Strategies After TAVI

Vascular access complications following transcatheter aortic valve implantation (TAVI) remain common. However, few studies compare vascular access closure methods.  Based on the CHOICE-CLOSURE and MASH...

TAVR in Young Low-Risk Patients

Transcatheter aortic valve replacement (TAVR) has established itself as an effective strategy for the treatment of severe aortic stenosis across different risk groups. While previous...

TAVR and Atrial Fibrillation: What Anticoagulants Should We Use?

The prevalence of atrial fibrillation (AF) in TAVR patients ranges from 15 to 30%, depending on series. This arrhythmia has been associated to higher...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

TCT 2024 | FAVOR III EUROPA

The study FAVOR III EUROPA, a randomized trial, included 2,000 patients with chronic coronary syndrome, or stabilized acute coronary syndrome, and intermediate lesions. 1,008...

TCT 2024 | TRISCEND II

This randomized study included 400 patients; 267 were treated with EVOQUE valve and 133 with optimal medical treatment (OMT). After one-year follow-up, there were no...

TCT 2024 – ACCESS-TAVI: Comparing Percutaneous Access Closure Strategies After TAVI

Vascular access complications following transcatheter aortic valve implantation (TAVI) remain common. However, few studies compare vascular access closure methods.  Based on the CHOICE-CLOSURE and MASH...