High Gradients After Valve-in-Valve

One of the limitations of aortic bioprostheses is their durability. When these devices fail, percutaneous valve implantation is a valid strategy. However, it has been shown that there may be high gradients involved.

Intervención tricuspídea heterotópica: Resultados de TricValve a un año

This gradient increase has been associated with worse outcomes and higher mortality rates, as observed in the PARTNER 2 study at 12 months. This, however, was not the case at the 5-year follow-up, highlighting the lack of conclusive evidence in this scenario.

An analysis was conducted on 12,122 patients who underwent transcatheter aortic valve implantation (TAVI) in surgically bioprosthetic aortic valves with severe structural deterioration. The primary endpoint at 12 months included all-cause death, stroke, myocardial infarction, or valve reintervention.

Patients were divided into four groups according to mean gradient: <10 mmHg (2272 patients), between 10 and <20 mmHg (5803 patients), between 20 and <30 mmHg (2889 patients), and >30 mmHg (1158 patients).

The mean age was 76 years, and 61% of patients were men. While groups were similar in many aspects, those with a post-procedural high gradient tended to have a higher initial gradient and a higher body mass index. They more frequently had a history of smoking, more aortic insufficiency, and an aortic valve area <1 cm2.

Read also: Glycemic Control and Coronary Stent Failure.

On the other hand, patients with a low gradient had higher rates of atrial fibrillation, lower ejection fraction, larger valve rings, elevated hemoglobin levels, and more urgent or emergent procedures.

The primary endpoint at 12 months was 11.1%, with a mortality rate of 7.6%, a myocardial infarction rate of 1%, and a valve reintervention rate of 1.2%.

A gradient ≥20 mmHg was associated with increased mortality at 12 months (adjusted hazard ratio [HR], 1.017 [95% confidence interval, 1.005–1.030] per mmHg; P=0.007).

Read also: Antiplatelet Treatment with Ticagrelor vs. Clopidogrel in Patients with Chronic Coronary Syndrome.

An adjusted analysis according to gradient (<10 mmHg, between 10 and >20 mmHg, between 20 and <30 mmHg, and ≥30 mmHg) showed increased mortality when the gradient was <10 mmHg or ≥30 mmHg.

Conclusion

In conclusion, there is a complex and nonlinear relationship between post-TAVI mean gradient in surgically deteriorated bioprosthetic aortic valves and clinical outcomes. There is a relative increase in adverse events in patients with low or extremely high gradients. Further studies are needed to better understand the factors influencing this relationship, especially in patients with low gradients.

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Impact of Elevated Gradients After Transcatheter Aortic Valve Implantation for Degenerated Surgical Aortic Valve Bioprostheses.

Reference: Riyad Yazan Kherallah, et al. Circ Cardiovasc Interv. 2024;17:e013558. DOI: 10.1161/CIRCINTERVENTIONS.123.013558.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Coronary Artery Disease in Aortic Stenosis: CABG + SAVR vs. TAVR + PCI: Data from Spanish Centers

Multiple randomized studies have shown comparable or superior efficacy of transcatheter aortic valve replacement (TAVR) vs. coronary artery bypass graft (CABG).  However, many of...

TCT 2024 | TRISCEND II: A New Hope in Percutaneous Tricuspid Valve Replacement

Advanced tricuspid regurgitation (TR) is a debilitating disease associated with heart failure and increased mortality.  Edge-to-edge repair has been shown to improve both clinical condition...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Severe Tricuspid Regurgitation: Surgical vs. Transcatheter Edge-to-Edge Repair

While highly prevalent, tricuspid regurgitation is a notably undertreated valvulopathy. Its progression has been associated with higher mortality and significant disability. According to the...

ACCESS-TAVI: Comparing Post TAVR Vascular Closure Devices

Transcatheter aortic valve replacement (TAVR) is a well-established option to treat elderly patients with severe symptomatic aortic valve stenosis. Technical advances and device development...

Endovascular Treatment of Iliofemoral Disease for the Improvement of Heart Failure with Preserved Ejection Fraction

Peripheral artery disease (PAD) is a significant risk factor in the development of difficult-to-treat conditions, such as heart failure with preserved ejection fraction (HFpEF)....