High Gradients After Valve-in-Valve

One of the limitations of aortic bioprostheses is their durability. When these devices fail, percutaneous valve implantation is a valid strategy. However, it has been shown that there may be high gradients involved.

Intervención tricuspídea heterotópica: Resultados de TricValve a un año

This gradient increase has been associated with worse outcomes and higher mortality rates, as observed in the PARTNER 2 study at 12 months. This, however, was not the case at the 5-year follow-up, highlighting the lack of conclusive evidence in this scenario.

An analysis was conducted on 12,122 patients who underwent transcatheter aortic valve implantation (TAVI) in surgically bioprosthetic aortic valves with severe structural deterioration. The primary endpoint at 12 months included all-cause death, stroke, myocardial infarction, or valve reintervention.

Patients were divided into four groups according to mean gradient: <10 mmHg (2272 patients), between 10 and <20 mmHg (5803 patients), between 20 and <30 mmHg (2889 patients), and >30 mmHg (1158 patients).

The mean age was 76 years, and 61% of patients were men. While groups were similar in many aspects, those with a post-procedural high gradient tended to have a higher initial gradient and a higher body mass index. They more frequently had a history of smoking, more aortic insufficiency, and an aortic valve area <1 cm2.

Read also: Glycemic Control and Coronary Stent Failure.

On the other hand, patients with a low gradient had higher rates of atrial fibrillation, lower ejection fraction, larger valve rings, elevated hemoglobin levels, and more urgent or emergent procedures.

The primary endpoint at 12 months was 11.1%, with a mortality rate of 7.6%, a myocardial infarction rate of 1%, and a valve reintervention rate of 1.2%.

A gradient ≥20 mmHg was associated with increased mortality at 12 months (adjusted hazard ratio [HR], 1.017 [95% confidence interval, 1.005–1.030] per mmHg; P=0.007).

Read also: Antiplatelet Treatment with Ticagrelor vs. Clopidogrel in Patients with Chronic Coronary Syndrome.

An adjusted analysis according to gradient (<10 mmHg, between 10 and >20 mmHg, between 20 and <30 mmHg, and ≥30 mmHg) showed increased mortality when the gradient was <10 mmHg or ≥30 mmHg.

Conclusion

In conclusion, there is a complex and nonlinear relationship between post-TAVI mean gradient in surgically deteriorated bioprosthetic aortic valves and clinical outcomes. There is a relative increase in adverse events in patients with low or extremely high gradients. Further studies are needed to better understand the factors influencing this relationship, especially in patients with low gradients.

Dr. Carlos Fava - Consejo Editorial SOLACI

Dr. Carlos Fava.
Member of the Editorial Board of SOLACI.org.

Original Title: Impact of Elevated Gradients After Transcatheter Aortic Valve Implantation for Degenerated Surgical Aortic Valve Bioprostheses.

Reference: Riyad Yazan Kherallah, et al. Circ Cardiovasc Interv. 2024;17:e013558. DOI: 10.1161/CIRCINTERVENTIONS.123.013558.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...

Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study

The expansion of transcatheter aortic valve implantation (TAVI) toward younger and lower-risk patients has increased the relevance of post-procedural coronary access. In this context,...

TEER plus optimal medical therapy versus medical therapy alone in functional mitral regurgitation

Mitral regurgitation (MR) is a highly prevalent valvular heart disease that, in advanced stages and when left untreated, is associated with reduced quality of...

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Duration of Smoking Cessation and Risk of Amputation After Revascularization in Critical Limb Ischemia

Critical limb ischemia (CLI) is associated with high rates of amputation and mortality. Although smoking cessation improves outcomes after revascularization, the impact of the...

Conservative management of endoleaks in complex aortic endografts under CT angiography follow-up

Endoleaks remain one of the leading causes of reintervention after endovascular repair of complex aortic aneurysms using fenestrated and/or branched endografts (F/B-EVAR). Traditionally, type...

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...