CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post TAVR coronary access. 

COMPARE TAVI: Resultados al año de un estudio aleatorizado que compara dos válvulas balón expandibles

The aim of this study was to assess the capacity for coronary cannulation after TAVR using Evolut FX with adequately positioned golden markers (aligned commissures). It also looked at the impact of commissural and coronary alignment with coronary CT. 

This was a multicenter study carried out in centers of US and Japan including consecutive patients with severe aortic stenosis implanted with the Evolut FX, receiving coronary angiogram and CT immediately after procedure. 

A total of 126 patients were included, mean age 81. Success cannulation rate of the left coronary (within the first 10 minutes) was 100%, while the right coronary reached 96.7%.

Read also: TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation.

At post implantation CT, most cases presented correct commissural alignment, though 25.4% showed mild misalignment. Anatomical factors associated with failed cannulation were evaluated and left main height and left commissural misalignment were identified as the main causes. On the other hand, predictors of failed right coronary artery cannulation were Valsalva sinuses width and commissural misalignment.

Presented by Yohei Ohno at Top Late-Breaking Trials, PCR London Valves, November 24, 2024, London, Great Britain.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Omar Tupayachi
Dr. Omar Tupayachi
Member of the Editorial Board of solaci.org

Más artículos de este Autor

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Transradial Aortic Valvuloplasty: Is Minimalism Worth It?

Balloon aortic valvuloplasty (BAV) has historically been used either as a bridge strategy, an assessment tool, or even palliative treatment in severe aortic stenosis...

Atrial Fibrillation After Percutaneous Patent Foramen Ovale Closure: Cohort Study with Continuous Implantable Cardiac Monitoring

Atrial fibrillation (AF) is a recognized complication following percutaneous closure of a patent foramen ovale (PFO), with reported incidences of up to 30% during...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Artículos relacionados

Jornadas SOLACIspot_img

Artículos recientes

Watch Again: Pulmonary Embolism in 2025 — Risk Stratification and Novel Therapeutic Approaches

Our webinar “Pulmonary Embolism in 2025: Risk Stratification and Novel Therapeutic Approaches” is now available to watch. The session took place on November 25,...

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....