ACC 2025 | BHF PROTECT-TAVI: Are Cerebral Protection Systems Necessary in TAVI?

TAVI has seen a steady increase in use, though stroke continues to be one of its unwanted complications, mostly ischemic and, less frequently, hemorrhagic.

The use of cerebral embolic protection (CEP) devices continues under debate, seeing as the several analyses conducted so far have failed to show conclusive or significant results as regards effectiveness. 

The BHF PROTECT-TAVI included 7,601 patients undergoing TAVI: 3,798 were treated with the SENTINEL device, while the rest formed the control group.

The primary endpoint was stroke within 72 hours after procedure or before hospital discharge.

Population mean age was 81, and 39% were women. Mean EUROSCORE was 2.4%. Regarding comorbidities: 68% had hypertension, 20% diabetes, 8% TIA, 6% previous stroke, 33% coronary artery disease, 13% heart failure, 33% atrial fibrillation, 33.5% peripheral vascular disease, 13% aortic arch abnormalities (including bovine arch), and 8% bicuspid aorta.

Read also: ACC 2025 | FAME 3: FFR Guided PCI vs CABG 5 Year Outcomes.

Ejection fraction was <30% in 5.5% of patients and 30% to 49% in 18%. Mean gradient was 43 mmHg. Nearly half of patients showed aortic annulus severe calcification, and 4% showed outflow tract calcification.

No significant differences were observed in primary end point, with 2.1% stroke incidence among CEP patients and 2.2% among control group patients (difference: –0.02 percentage points; 95% CI: –0.68 to 0.63; p=0.94). Also, there were no differences in severe stroke incidence (0.5% vs. 0.5%; difference: 0.0 percentage points; 95% CI: –0.3 to 0.3), and most strokes occurred within the first 24 hours after procedure.

Read also: ACC-2025 Congress Second Day Key Studies.

Likewise, no differences were observed in disabling stroke between weeks 6 and 8 after TAVI (1.2% vs. 1.4%; difference: –0.2 percentage points; 95% CI: –0.7 to 0.4), or mortality within 72 hours, during hospitalization, or at 8 weeks.

Conclusion

Among patients undergoing TAVI, the routine use of cerebral protection devices did not reduce stroke incidence within the first 72 hours.

Original Title: Routine Cerebral Embolic Protection during Transcatheter Aortic-Valve Implantation.

Reference: Rajesh K. Kharbanda, et al. NEJM DOI: 10.1056/NEJMoa2415120.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Carlos Fava
Dr. Carlos Fava
Member of the Editorial Board of solaci.org

More articles by this author

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

One-Year Results of ENCIRCLE: Percutaneous Mitral Valve Replacement in Patients Ineligible for Surgery or TEER

Symptomatic mitral regurgitation (MR) in patients who are not candidates for surgery or transcatheter edge-to-edge repair (TEER) remains a highly complex clinical scenario associated...

Can Coronary CT Angiography Replace Invasive Coronary Angiography in Pre-TAVI Coronary Assessment?

Coronary artery disease coexists in approximately half of patients undergoing transcatheter aortic valve implantation, making coronary assessment prior to the procedure essential. Invasive coronary...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...