Balloon-Expandable Myval Valve Four-Year Outcomes

The expanding indication of transcatheter aortic valve replacement (TAVR) to younger patients or those at lower surgical risk has driven research towards providing stronger evidence as regards long-term durability.

Incidencia, características y tratamiento de la trombosis valvular post TAVI

The Myval valve (Meril Life Sciences), a balloon-expandable system developed as an alternative to SAPIEN valves, has sparked growing interest, especially following the LANDMARK data.

A multicenter study led by Jain et al. has contributed with important evidence on Myval performance and durability at 4 years. The study included 366 patients with severe aortic stenosis treated between 2017 and 2020, and assessed parameters defined by VARC-3, including hemodynamic valve deterioration (HVD), bioprosthetic valve failure (BVF), and patient-prosthesis mismatch (PPM).

Patient mean age was 75.9 and they were predominantly male, with significant comorbidity burden: 55.2% with coronary artery disease and 37.4% with chronic kidney disease. The transfemoral approach was used in 98.9% of cases, with 7.9% post-dilatation rate. 

Read also: Statins and Small Abdominal Aortic Aneurysms: Unexpected Aid?

After four years, overall survival was 81.8%, with 98.5% stroke-free survival rate. BVF Incidence was 3.3% (criterion 1), with no need for reintervention and no valve-related deaths. Mean aortic gradients remained stable at 11.96 mmHg, with mean effective orifice area 1.66 cm². 

Grade 2 HVD was seen in 9.7% and grade 3 in 0.7%. Moderate or greater aortic regurgitation reached 9.2%, while severe PPM was reported in 2.1%. These results are comparable to contemporary series of both balloon-expandable and self-expanding valves.

Conclusions

They study by Jain et al. supports Myval durability in a real population, with comparable results to those obtained with other prosthesis normally used. Sustained hemodynamic stability and low complications incidence reinforce Myval as a valid alternative in the context of TAVR.

Original Title: Four-year durability of the Myval balloon-expandable transcatheter aortic valve.

Reference: Jain A, Jose J, Montorfano M, Nissen H, Martin P, Seth A, Stambuk K, Sengottuvelu G, Abdurashid M, García-Gómez M, Fernandez-Cordón C, Rodriguez M, Jorgensen MD, Campo A, Serrador A, Vallinas-Hernandez S, Carrasco-Moraleja M, San Román A, Amat-Santos IJ. Four-year durability of the Myval balloon-expandable transcatheter aortic valve. EuroIntervention. 2025 Jul 7;21(13):e758-e765. doi: 10.4244/EIJ-D-24-01112. PMID: 40627005; PMCID: PMC12207338.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Omar Tupayachi
Dr. Omar Tupayachi
Member of the Editorial Board of solaci.org

More articles by this author

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Transradial Aortic Valvuloplasty: Is Minimalism Worth It?

Balloon aortic valvuloplasty (BAV) has historically been used either as a bridge strategy, an assessment tool, or even palliative treatment in severe aortic stenosis...

Atrial Fibrillation After Percutaneous Patent Foramen Ovale Closure: Cohort Study with Continuous Implantable Cardiac Monitoring

Atrial fibrillation (AF) is a recognized complication following percutaneous closure of a patent foramen ovale (PFO), with reported incidences of up to 30% during...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....