Conservative management of endoleaks in complex aortic endografts under CT angiography follow-up

Endoleaks remain one of the leading causes of reintervention after endovascular repair of complex aortic aneurysms using fenestrated and/or branched endografts (F/B-EVAR). Traditionally, type I and type III endoleaks have been considered indications for early correction due to their association with persistent pressurization of the aneurysm sac and an increased risk of rupture. However, recent evidence suggests that some endoleaks may resolve spontaneously without increasing this risk. In this context, the present study evaluated the spontaneous resolution of endoleaks and associated factors in patients undergoing F/B-EVAR managed with a conservative strategy based on surveillance with computed tomography angiography (CTA).

A single-center retrospective study was conducted at the Division of Vascular Surgery of the Medical University of Vienna (Vienna, Austria), including 230 consecutive patients treated between January 2015 and June 2024 for complex aortic aneurysms, comprising juxtarenal, pararenal, paravisceral abdominal, and thoracoabdominal aneurysms. The median age was 74 ± 7 years, with a predominance of men (79%). On CTA performed prior to hospital discharge, 75% (n = 172) of patients presented some type of endoleak (type I, II, III, and mixed combinations). 

All patients were followed using a standardized CTA protocol: those with type I and/or III endoleaks, or mixed endoleaks without sac enlargement, underwent tomographic follow-up at 6 months, whereas patients with isolated type II endoleaks or no endoleak were evaluated at 12 months. Endoleak resolution was defined as complete disappearance on CTA without the need for reintervention. Secondary intervention was indicated only in cases of aneurysm sac growth greater than 5 mm at 6 months or greater than 10 mm at 12 months.

Read also: Long-Term Predictors of Valve Deterioration After TAVI.

The primary endpoint was spontaneous resolution of the endoleak without the need for reintervention during follow-up. Secondary endpoints included identification of clinical, procedural, and morphological factors associated with spontaneous resolution, as well as aneurysm sac evolution.

During follow-up, type I endoleaks did not show spontaneous resolution. In contrast, type III endoleaks demonstrated a high rate of spontaneous closure, reaching 83% at 24 months, with most cases occurring within the first 12 months. Mixed endoleaks exhibited a significantly lower resolution rate (28% at 24 months; p < 0.001); however, the combined type II/III subtype showed a more favorable course, with spontaneous resolution in 50% of cases at 12 months.

No aneurysm ruptures were recorded throughout the follow-up period. When analyzing endoleak volume using a cutoff value of 9.37 mL, smaller and larger endoleaks showed comparable resolution rates up to 12 months (44% vs. 36%). Beyond this period, smaller-volume endoleaks demonstrated a significantly higher probability of spontaneous resolution (p = 0.039).

Read also: Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study.

In multivariate analysis, a smaller maximum aortic diameter was independently associated with a higher likelihood of spontaneous resolution (OR 0.963; p = 0.011). Reduction in aneurysm sac size was the strongest predictor of spontaneous closure (OR 9.706; p < 0.001), while a history of peripheral arterial disease was also favorably associated (OR 3.617; p = 0.007). Initial endoleak volume was not identified as an independent predictor (p = 0.10).

Conclusion

In patients undergoing complex endovascular repair with branched and/or fenestrated endografts, structured surveillance with CTA proved to be a safe and effective strategy for the conservative management of type III endoleaks and mixed type II/III endoleaks, provided that aneurysm sac dynamics remain stable. In this study, more than 80% of type III endoleaks resolved spontaneously at 24 months, with no aneurysm ruptures reported, allowing the avoidance of a significant number of reinterventions.

Original Title: CTA Surveillance for Conservative Endoleak Treatment following Complex Endovascular Aneurysm Repair.

More articles by this author

AHA/ACC Guideline on the Management of Acute Pulmonary Embolism 2026

The 2026 ACC/AHA guideline for the management of acute pulmonary embolism (PE) introduces a conceptual shift by replacing the traditional “risk-based” classification with an...

FFR Assessment for the Selection of Hypertensive Patients Who Benefit from Renal Stenting

Atherosclerotic renal artery stenosis (ARAS) represents one of the main causes of secondary hypertension (HTN) and is associated with a higher risk of renal...

Transcatheter Deep Vein Arterialization in Critical Limb Ischemia Without Revascularization Options

Chronic limb-threatening ischemia in patients without conventional revascularization options represents one of the most challenging scenarios within peripheral arterial disease, with 1-year major amputation...

Duration of Smoking Cessation and Risk of Amputation After Revascularization in Critical Limb Ischemia

Critical limb ischemia (CLI) is associated with high rates of amputation and mortality. Although smoking cessation improves outcomes after revascularization, the impact of the...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...