Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

Rotational atherectomy and its technical secrets: use of floppy or ES guidewire

Rotational atherectomy (RA) remains a very useful tool in the management of severe coronary calcification. However, many of its technical aspects rely more on operator experience than on solid evidence. Among the variables involved during the procedure, the type of guidewire used (Rotawire floppy or extra-support) and the ablation speed may play an important role.

Kawamura et al. conducted an experimental study evaluating the interaction between ablation speed and the type of RotaWire on the direction and pattern of plaque modification. The study was performed using an in vitro model with the HEARTROID simulator and pre- and post-procedural OCT analysis in 20 calcified lesions of the left anterior descending artery in the model. Two types of guidewires—floppy and extra-support—were compared at speeds of 140,000 and 190,000 rpm.

Simulation results showed that the combination of the extra-support guidewire with high speed resulted in the smallest discrepancy between the expected position and the actual direction of ablation (wire bias), indicating a more controlled behavior. In contrast, with the floppy guidewire, high speed was associated with greater discrepancy between the expected and the observed ablation compared with low speed.

When evaluating the ablated area, a tendency toward greater debulking at lower speed was observed with the floppy guidewire, although without statistically significant differences. Conversely, with the extra-support guidewire, higher speed was associated with a larger ablated area and greater depth compared with lower speed, suggesting that the effect of speed largely depends on the level of guidewire support.

Read also: Percutaneous Mechanical Aspiration versus Surgical Treatment of Tricuspid Valve Endocarditis.

Another variable evaluated was the position of the guiding catheter. Changes were observed in the guidewire orbit and in the direction of ablation depending on the catheter position within the artery, whether more superficial or deeper (deep intubation), with a more precise behavior when the catheter was positioned deeper.

Conclusions

The main limitation of the study is its experimental nature and the absence of clinical events. Nevertheless, understanding the behavior of the equipment is important, and based on these findings it can be suggested that in rotational atherectomy the combination of an extra-support guidewire and high-speed ablation at 190,000 rpm demonstrated the most predictable and controlled effect.

Original Title: Difference Between Low‐Speed and High‐Speed Rotational Atherectomy Using Two Types of Guidewires.

Reference: Kawamura A, Okayama K, Nohara H, Nakano T, Sakata Y. Difference Between Low-Speed and High-Speed Rotational Atherectomy Using Two Types of Guidewires. Catheter Cardiovasc Interv. 2026 Feb 9. doi: 10.1002/ccd.70514. Epub ahead of print. PMID: 41662389.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

Dr. Omar Tupayachi
Dr. Omar Tupayachi
Member of the Editorial Board of solaci.org

More articles by this author

DK-Crush in Left Main Bifurcations: Rewiring Selection According to Bifurcation Angle

Complex coronary bifurcation PCI, especially in the left main coronary artery (LMCA), represents one of the most technically demanding scenarios in interventional cardiology. Among...

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

SCAI 2026 | SELUTION DeNovo subanalysis: Use of sirolimus-eluting balloon in acute coronary syndrome

Percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation remains the predominant strategy in the setting of acute coronary syndrome (ACS). However, in recent...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

DK-Crush in Left Main Bifurcations: Rewiring Selection According to Bifurcation Angle

Complex coronary bifurcation PCI, especially in the left main coronary artery (LMCA), represents one of the most technically demanding scenarios in interventional cardiology. Among...

Percutaneous Closure of Patent Foramen Ovale in Patients Over 60 Years Old With Cryptogenic Stroke: A Safe and Effective Strategy?

Cryptogenic stroke accounts for up to one-third of all ischemic strokes and remains strongly associated with the presence of a patent foramen ovale (PFO),...

Left Atrial Appendage Closure: Implantation Depth Could Determine Thrombosis Risk

Left atrial appendage closure (LAAC) has undergone significant advances over the past two decades. This progress has been driven by the development of new...