Stress echocardiography in low flow, low gradient aortic stenosis with deteriorated systolic function

Echocardiography  
Favaloro Foundation. Buenos Aires, Argentina.

JACC Cardiovascular Imaging has recently published a retrospective analysis including severe aortic stenosis patients (< 1 cm²), with low gradient (mean aortic gradient

Patients that had undergone dobutamine stress echocardiography (DSE) to distinguish pseudo aortic stenosis (n=49) were selected. These results were used to determine flow reserve (FR). The study aims to evaluate the efficacy of this approach in assessing intervention risk and long term evolution in patients with severe aortic stenosis, low gradient and ventricular function deterioration, with either reduced or normal ejection fraction, undergoing TAVR.

Flow reserve was defined as a 20% increase in stroke volume index (SVI) from rest to peak dobutamine infusion, compared to baseline echocardiography. After TAVR, patients were followed up to assess mortality.

The analysis included 49 elderly patients (80±8), 70% men, 88% white.  Prosthesis of choice was SAPIEN transcatheter heart valve from Edwards Lifescience. Approaches of choice were transfemoral (60%) and transapical (40%). 

Mean ejection fraction was 38±14%. Most patients (70%) presented

More articles by this author

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

UNICORN Technique to Prevent Coronary Obstruction During TAVI: Initial Results From a Multicenter Study

Coronary obstruction is an uncommon but potentially catastrophic complication of transcatheter aortic valve implantation (TAVI), particularly in valve-in-valve procedures, TAV-in-TAV interventions, or in patients...

Supera vs. Eluvia at 3 Years in Severely Calcified Femoropopliteal Lesions

Severe calcification remains one of the main predictors of restenosis and the need for repeat revascularization following endovascular treatment of femoropopliteal disease. In this...

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...