I-LOVE-IT2: Drug-eluting stents with a permanent polymer versus biodegradable in the same cobalt chromium platform

There is no strong evidence in the literature that the polymer type isolated (permanent or degradable) influences clinical outcomes after angioplasty and if the time of double anti-aggregation should be different with the degradable polymer. This work, with non-inferiority design, aimed to compare the sirolimus-eluting biodegradable polymer stent (Tivoli) versus the permanent polymer sirolimus-eluting stent (Firebird 2). The primary end point was a composite of cardiac death, myocardial infarction related to the vessel and target vessel revascularization. 

2737 patients from 32 Chinese centers were randomized, demonstrating non-inferiority of the biodegradable polymer stent at 12 months with 6.3% events versus 6.1% of the permanent polymer stent. Comparing each component of the primary end point individually no significant differences were observed between the two devices. 

1_bo_xu
Bo Xu
2014-09-17

Original title: A Prospective, Randomized Trial of a Biodegradable Polymer, Cobalt Chromium, Sirolimus-Eluting Stent Versus a Durable Polymer, Cobalt Chromium, Sirolimus-Eluting Stent in Patients with Coronary Artery Disease.

More articles by this author

EVERBIO II: Bio-absorbable stent Absorb versus everolimus-eluting or biolimus stents

The new generation drug-eluting everolimus or biolimus stents have proved superior to the first generation. However, neo intimal proliferation and late thrombosis remains a...

EXCITE ISR: Excimer laser versus balloon angioplasty for stent restenosis of the superficial femoral

This multicenter, prospective, randomized trial compared the Excimer laser atherectomy (Excimer Laser Atherectomy = ELA, Spectranetics, Inc.) with a balloon angioplasty in patients with...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long Term Results of the International Chimney Registry

The International Chimney Registry was an observational study aimed at assessing the use of chimney stenting during TAVR either to predict or treat coronary...

CANNULATE TAVR extended study: Impact of Commissural and Coronary Alignment in Coronary Cannulation Following TAVR with Evolut Fx

The new valve Evolut FX has shown better commissural alignment vs. its predecessor Evolut Pro+. Prior studies have already shown commissure alignment facilitates post...

TRISCEND II: Transcatheter Replacement vs. Medical Treatment for Tricuspid Regurgitation

The EVOQUE device is designed with an intra-annular sealing system that provides excellent anatomical compatibility and an adaptable shape. It is currently available in...