Low gradient and LV Dysfunction: TAVI or not?

Original Title: Impact of ejection fraction and aortic valve gradient on outcomes of transcatheter aortic valve replacement.

Reference: Baron SJ et al. J Am Coll Cardiol. 2016;67:2349-2358.

 

Stethoscope with heart on suit background, close-up

Low aortic valve gradient and left ventricular dysfunction are frequent in patients with severe aortic stenosis undergoing transcatheter aortic valve replacement (TAVI) but only low aortic valve gradient is associated with worse prognosis at one year, according to the recently published Transcatheter Valve Therapy (TVT) registry.

These findings suggest that low aortic valve gradient in patients with aortic stenosis is an important factor to consider when assessing risk/benefit ratio, since it has an important impact prognosis compared to low ejection fraction, which doesn’t seem as important.

Aside from this, neither of these two factors, separately or combined, seems to be enough not to prescribe TAVI.

Patients with severe LV dysfunction and low aortic valve gradient have 33% 1 year mortality, as observed in patients with this characteristics submitted to medical treatment in the PARTNER B.

This trial assessed data from 11292 patients undergoing TAVI between 2011 and 2014 included in the TVT registry (Society of Thoracic Surgeons/American College of Cardiology).

Patients were divided in three groups according to ventricular dysfunction:

  • Severe dysfunction (<30%).
  • Mild to moderate dysfunction (30-50%).
  • Preserved (>50%).

Aortic valve gradient was considered low (<40 mmHg) or high (≥40 mmHg). Mean gradient was lower in patient with severe LV dysfunction. LV function was worse in patients with low gradient.

Outcomes:

  • Patents with LV dysfunction and low aortic valve gradient had more prolonged post procedure hospitalization and had higher in hospital mortality. AT one year follow up, both factors were associated with higher risk of death and heart failure.
  • Patients with preserved LV dysfunction and high gradient had better prognosis at one year (23.6% mortality and 11.2% heart failure) compared to those with LV dysfunction and low gradient, with much worse prognosis (33.1% y 23.6%, respectively).
  • In multivariable analyzis, only low gradient was associated to higher mortality (HR 1.21; CI 95% 1.11-1.32) and recurrent heart failure (HR 1.52; CI 95% 1.36-1.69). These events and LV dysfunction were not significantly associated.

Editorial Comment

The greatest strength of this study was the big number of real world patients, and the limitation, that there was no “core lab” to adjudicate events, echocardiographic data was limited and of course there was no control group.

The information on aortic valve gradient, valve area, flow and ejection fraction, should be systematically integrated when stratifying severe aortic stenosis patients.

More articles by this author

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Is it safe to use negative chronotropic drugs early after TAVI?

TAVI is associated with a relevant incidence of conduction system disturbances and the development of atrioventricular block that may require permanent pacemaker implantation. Many...

Transapical TMVR in High Risk Patients: Intrepid 5-Year Outcomes

Moderate to severe mitral valve regurgitation (MR) continues is still a high prevalence condition with bad prognosis, particularly among the elderly with left ventricular...

Impact of Balloon Post-Dilation on the Long-Term Durability of Bioprostheses after TAVR

Balloon post-dilation (BPD) during transcatheter aortic valve replacement (TAVR) allows for the optimization of prosthesis expansion and the reduction of residual paravalvular aortic regurgitation....

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

VECTOR: First Percutaneous Aorto-Coronary Bypass Case, a New Conceptual Approach

Coronary obstruction represents one of the most severe complications associated with transcatheter aortic valve implantation, particularly in valve-in-valve scenarios involving surgical bioprostheses, narrow aortic...

Comparison of strategies: NMA of IVUS, OCT, or angiography in complex lesions

Percutaneous coronary intervention (PCI) in complex lesions continues to represent a technical challenge in contemporary interventional cardiology. Angiography, although it remains the most widely...

Is upper-limb aerobic training an effective alternative to lower-limb exercise in peripheral artery disease?

Peripheral artery disease is associated with impaired functional capacity, reduced walking distance, and poorer quality of life, and structured exercise is a class I...