Percutaneous Repair of Paravalvular Leaks After TAVR: The Challenge of Identifying Eligible Subjects

Courtesy of Dr. Carlos Fava.

Percutaneous Repair of Paravalvular Leaks After TAVRThis study enrolled 72 patients who underwent transcatheter aortic valve replacement with an Edwards Sapiens valve, and then experienced a leak of at least moderate severity.

 

Fifteen of them underwent a percutaneous leak repair after identification of the leak mostly through the presence of symptoms.

 

Both groups were similar. Patients who underwent percutaneous repair were younger. Plugs were used in the repair, and no patient experienced hemolytic anemia.

 

The procedure was successful in 13 patients. In 2 of them, crossing of the leak was impossible to achieve. One patient who continued experiencing symptoms required a new intervention.

 

At 20 months of follow-up, there was 1 (13.8%) death in the group of patients who underwent a leak repair and 24 (42%) deaths in the control group. Leak repairs benefited patients, who experienced improvement in symptom status, reduction in subsequent hospitalizations, and reduction in B-type natriuretic peptide levels.

 

Conclusion

Transcatheter repair of paravalvular leaks after TAVR can be safe and effective in a selected patient group and may lead to reductions in hospitalizations, and improvement in symptoms and long-term survival.

 

Editorial Comment

Paravalvular leaks with current technology occur in 13%-15% of cases and are one of the technological challenges to be worked out in the future.

 

In these cases, identifying patients eligible for this procedure is of the utmost importance, since leaks can be repaired safely and effectively, improving quality of life and long-term survival.

 

Courtesy of Dr. Carlos Fava. Buenos Aires Favaloro Foundation, Argentina.

 

Title: Outcome of Paravalvular Leak Repair After Transcatheter Aortic Valve Replacement with a Balloon-Expandable Prothesis.

 Reference: Abhijeet Dhoble, et al. Catheterization and Cardiovascular Interventions 2017;89:462-468.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

Beyond TAVI: Cardiac Rehabilitation as a Determinant of Clinical Outcomes

Aortic stenosis is an increasingly prevalent condition associated with population aging, with a prevalence of approximately 3.4% in individuals over 75 years of age...

Comparative outcomes between transaxillary approach and thoracotomy-based approaches in TAVI with alternative access

TAVI has become the standard treatment for high-risk aortic stenosis. When transfemoral access is not feasible (approximately 10–15%), alternative approaches are used: transaxillary (subclavian...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...