Day 1 articles

SCAAR: Heparin versus bivalirudin in patients with myocardial infarction without ST segment elevation.

SCAAR: Heparin versus bivalirudin in patients with myocardial infarction without ST segment elevation.

We evaluated 41,537 patients admitted with myocardial infarction without ST elevation on the SCAAR register and who had not received IIBIIIB glycoprotein inhibitors and divided them into two groups: 31,351 patients who received heparin versus 10,186 who received bivalirudin. We adjusted baseline characteristics of the two groups using the Propensity score with the exception of

SOURCE XT: Results of the latest generation of the Edwards valve

The first generation of the Edwards valve was stainless steel and bovine pericardium with a profile of 22 to 24 Fr for transfemoral access and up to 33 Fr to apical access. From 2010 it became cobalt chromium bovine pericardium with a higher profile, (18-19 Fr for transfemoral and 24-26 Fr for transapical). 2,688 patients

EnligHTN: treatment of refractory hypertension by catheterization

Lowering blood pressure with renal denervation has been demonstrated in previous studies but unfortunately there was not much data regarding the reduction of clinical events. This study will enroll patients between 40 and 55 years of age with resistant hypertension plus risk factors for major cardiovascular events. A five year follow-up has been planned. The

BIOFLOW II. Stent eluidor de sirolimus com polímero degradável.

This non-inferiority design study compared the sirolimus-eluting stent with biodegradable polymer versus everolimus-eluting stent with permanent polymer in de novo coronary lesions. The primary endpoint was late lumen loss at nine months. We Included 440 patients with stable coronary lesions randomized 2:1 to receive the new sirolimus eluting stent with biodegradable polymer versus everolimus eluting

SYNTAX II: multiple vessels using iFR / FFR and IVUS

This study is still in progress and includes patients using SYNTAX II score based on functional invasive evaluation with iFR / FFR and performing angioplasty guided by IVUS using the biodegradable polymer everolimus eluting stent. The study seeks to prove superiority versus the first generation paclitaxel-eluting stent and non-inferiority versus surgery using historical data. We

EUROMAX: Bivalirudin during transport to primary angioplasty

The HORIZONS AMI trial showed the usefulness of bivalirudin in reducing mortality and bleeding compared with the use of heparin plus glycoprotein IIBIIIA. However, some questions remained unanswered: What is the utility of starting the infusion during the ambulance journey? Is it possible to reduce the risk of acute thrombosis by extending bivalirudin infusion or

DESolveNx trial: Results of the new bioabsorbable platform

This new device consists of a novolimus releasing bioabsorbable polylactic acid platform that in vitro studies has shown equivalence to a Cypher stent. This device, also in vitro , showed a degradation time of one year and safety during post expansion, reaching 4.8 mm without fracturing. This is the first human trial and follow-up with

Top