Plug versus coils for embolization of the internal iliac artery stent implantation.

Original title: Comparison of outcomes with coils versus vascular plug embolization of the internal iliac artery for endovascular aortoiliac aneurysm repair. Reference: Evan J. Ryer et al. J Vasc Surg 2012;56:1239-45

20% of patients with abdominal aortic aneurysm (AAA) present a compromise of the common distal iliac artery, these often require the stent to cover up to the external iliac. Retrograde flow through the internal iliac artery can pressurize the bag and generate a type II endoleak which requires embolization. 

Both coils and the Amplatzer vascular plug are useful for embolization but no studies have compared them. 

This study included 53 consecutive patients, analyzed retrospectively, who underwent embolization of the internal iliac artery. 29 patients received coils, (Cook Medical Inc, Bloomington, Ind), and 28 an Amplatzer vascular plug (AGA Medical Corporation). 63% underwent embolization prior to the stent implantation procedure. Coils were used per patient 5.8 versus 1.1 plug. Fluoroscopy time was significantly lower with the use of a plug, (coil 32.6 ± 14.6 min vs. plug 14.4 ± 8.6 min p = 0.002). No expected embolization occurred in 2 patients from the coil group, these could be extracted as endovascular uncomplicated. 

In follow-up 39.3 ± 24.2 months, there were three type II endoleaks in the plug group. None of these endoleaks were related to the internal iliac artery and were not associated with bag growth. Persistent buttock claudication occurred in 13.8% (n = 4) of the coil group and in 14.3% of the plug group (n = 4). There was no colonic or pelvic ischemia in any patient. In the cost analysis the authors found no differences between the groups.

Conclusion 

Both devices were equally effective and safe for internal iliac artery embolization in the context of stent implantation with a shorter procedure and fluoroscopy using a plug.

Editorial Comment:

This study was not randomized so the choice of the device may have been influenced by the anatomical complexity. It is also important to consider the costs where we work, because if this analysis was performed in Argentina for example, the coils would be significantly less expensive. It is necessary to counterbalance the costs with a shorter procedure and fluoroscopy.

SOLACI.ORG

More articles by this author

Is upper-limb aerobic training an effective alternative to lower-limb exercise in peripheral artery disease?

Peripheral artery disease is associated with impaired functional capacity, reduced walking distance, and poorer quality of life, and structured exercise is a class I...

Endoleaks after endovascular repair of complex aortic aneurysms: always reintervene or monitor with CTA?

Endovascular repair of thoracoabdominal aneurysms requiring sealing above the renal arteries, with preservation of visceral vessels using fenestrated and/or branched devices (F/B-EVAR), has become...

A New Asymptomatic Carotid Stenosis Paradigm? CREST-2 Trial Unified Results

Severe asymptomatic carotid stenosis continues to be controversial seeing the optimization of intensive medical therapy (IMT) and the availability lower periprocedural risk revascularization techniques....

Impact of Baseline Systolic Blood Pressure on Blood Pressure Changes Following Renal Denervation

Renal denervation (RDN) is a guideline-recommended therapy to reduce blood pressure in patients with uncontrolled hypertension, although uncertainties remain regarding which factors best predict...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Long-Term Predictors of Valve Deterioration After TAVI

Transcatheter aortic valve implantation (TAVI) has become an innovative technology for the treatment of patients with severe aortic valve stenosis. Initially implemented in elderly...

Coronary access after TAVI with fourth- and fifth-generation Evolut valves: the EPROMPT-CA study

The expansion of transcatheter aortic valve implantation (TAVI) toward younger and lower-risk patients has increased the relevance of post-procedural coronary access. In this context,...

Morpheus Global Registry: Safety and efficacy of the long tapered BioMime™ Morph stent in complex coronary lesions

Percutaneous coronary intervention in long coronary lesions continues to represent a technical and clinical challenge, in which the use of conventional cylindrical stents may...