Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

REPRISE III: Lotus and CoreValve Compared in High-Risk or Inoperable Patients

REPRISE III: Lotus and CoreValve Compared in High-Risk or Inoperable PatientsThe efficacy of transcatheter aortic valve replacement (TAVR) has been well-established. However, its limitations include suboptimal deployment and paravalvular leak. The Lotus system is a fully repositionable and retrievable device with controlled mechanical expansion. It features an adaptive seal to minimize paravalvular leak, it does not require early pacing during deployment, and, given its early functioning, the procedure is very stable, hemodynamically speaking.

 

This was a prospective noninferiority multicenter (United States, Canada, Germany, France, Australia, and Netherlands) study that randomized patients 2:1 to Lotus vs. CoreValve. Subjects had severe aortic stenosis, and presented high surgical risk or were inoperable.

 

The primary safety endpoint was a composite of death, stroke, major bleeding, renal insufficiency, and major vascular complications at 30 days. The primary efficacy endpoint was a composite of death, disabling stroke, and moderate or greater paravalvular leak at 1 year.

 

The study included 912 pacientes (CoreValve: 305; Lotus: 607) in 55 centers in the aforementioned countries, between 2014 and 2015.

 

The Lotus valve was noninferior as regards the primary safety endpoint at 30 days (Lotus, 19%, vs. CoreValve, 16%; p = 0.001 for noninferiority). Lotus was associated with a higher need for new pacemaker implantation (29.1 vs. 15.8; p < 0.001).

 

At 1 year, the curves for the primary safety endpoint were yuxtaposed (Lotus, 30.7%, vs. CoreValve, 30.2%; p = 0,83).

 

The Lotus device was also noninferior for the primary efficacy endpoint (Lotus, 16.7%, vs. CoreValve, 29%; p < 0.001 for noninferiority).

 

Both valves presented similar mortality rates (CoreValve, 13.7%, vs. Lotus, 11.9%; p = 0.48). However, CoreValve presented a higher rate of moderate to greater paravalvular leak (11.1% vs. 2.0%; p < 0.001) and a higher rate of disabling stroke (CoreValve, 7.3%, vs. Lotus, 3.6%; p = 0.02).

 

Conclusion

The Lotus valve turned out to be safe and effective when compared to the self-expanding device commercially available at the time of this study, CoreValve.

 

Dr. Ted Feldman
Dr. Ted Feldman

Original title: A Prospective, Randomised Investigation of a Novel Transcatheter Aortic Valve Implantation System: The REPRISE III Trial.

Presenter: Ted E. Feldman.

 

 

FeldmanTed


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

Beyond TAVI: Cardiac Rehabilitation as a Determinant of Clinical Outcomes

Aortic stenosis is an increasingly prevalent condition associated with population aging, with a prevalence of approximately 3.4% in individuals over 75 years of age...

Comparative outcomes between transaxillary approach and thoracotomy-based approaches in TAVI with alternative access

TAVI has become the standard treatment for high-risk aortic stenosis. When transfemoral access is not feasible (approximately 10–15%), alternative approaches are used: transaxillary (subclavian...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Deep vein arterialization as an alternative in patients with critical limb ischemia without conventional options

Critical limb ischemia (CLI) represents one of the most advanced stages of peripheral arterial disease (PAD). In a significant proportion of patients, distal anatomy,...