REPRISE III: Lotus and CoreValve Compared in High-Risk or Inoperable Patients

REPRISE III: Lotus and CoreValve Compared in High-Risk or Inoperable PatientsThe efficacy of transcatheter aortic valve replacement (TAVR) has been well-established. However, its limitations include suboptimal deployment and paravalvular leak. The Lotus system is a fully repositionable and retrievable device with controlled mechanical expansion. It features an adaptive seal to minimize paravalvular leak, it does not require early pacing during deployment, and, given its early functioning, the procedure is very stable, hemodynamically speaking.

 

This was a prospective noninferiority multicenter (United States, Canada, Germany, France, Australia, and Netherlands) study that randomized patients 2:1 to Lotus vs. CoreValve. Subjects had severe aortic stenosis, and presented high surgical risk or were inoperable.

 

The primary safety endpoint was a composite of death, stroke, major bleeding, renal insufficiency, and major vascular complications at 30 days. The primary efficacy endpoint was a composite of death, disabling stroke, and moderate or greater paravalvular leak at 1 year.

 

The study included 912 pacientes (CoreValve: 305; Lotus: 607) in 55 centers in the aforementioned countries, between 2014 and 2015.

 

The Lotus valve was noninferior as regards the primary safety endpoint at 30 days (Lotus, 19%, vs. CoreValve, 16%; p = 0.001 for noninferiority). Lotus was associated with a higher need for new pacemaker implantation (29.1 vs. 15.8; p < 0.001).

 

At 1 year, the curves for the primary safety endpoint were yuxtaposed (Lotus, 30.7%, vs. CoreValve, 30.2%; p = 0,83).

 

The Lotus device was also noninferior for the primary efficacy endpoint (Lotus, 16.7%, vs. CoreValve, 29%; p < 0.001 for noninferiority).

 

Both valves presented similar mortality rates (CoreValve, 13.7%, vs. Lotus, 11.9%; p = 0.48). However, CoreValve presented a higher rate of moderate to greater paravalvular leak (11.1% vs. 2.0%; p < 0.001) and a higher rate of disabling stroke (CoreValve, 7.3%, vs. Lotus, 3.6%; p = 0.02).

 

Conclusion

The Lotus valve turned out to be safe and effective when compared to the self-expanding device commercially available at the time of this study, CoreValve.

 

Dr. Ted Feldman
Dr. Ted Feldman

Original title: A Prospective, Randomised Investigation of a Novel Transcatheter Aortic Valve Implantation System: The REPRISE III Trial.

Presenter: Ted E. Feldman.

 

 


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Hemodynamic Outcomes of Edge-to-Edge Repair in Degenerative and Functional Mitral Regurgitation

Transcatheter edge-to-edge mitral valve repair (M-TEER) has become an established therapeutic option for mitral valve disease. Among the available techniques, M-TEER using the MitraClip...

SAPIEN 3 TAVI Durability: Ten-Year Follow-Up in Intermediate-Risk Patients

The durability of transcatheter bioprosthetic valves used in TAVI remains one of the key unanswered questions as indications continue to expand toward patients with...

Inflammation after TAVI: An Emerging Therapeutic Target?

Conduction disturbances and the need for permanent pacemaker implantation remain common complications following TAVI, with an incidence approaching 15%. Although they have traditionally been...

Coronary Obstruction During TAVI: A New Volumetric Index to Consider

Coronary obstruction during TAVI is an uncommon but potentially catastrophic complication, particularly in valve-in-valve procedures, in anatomies with small sinuses of Valsalva, low coronary...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Supera vs. Eluvia at 3 Years in Severely Calcified Femoropopliteal Lesions

Severe calcification remains one of the main predictors of restenosis and the need for repeat revascularization following endovascular treatment of femoropopliteal disease. In this...

Is IVUS Always Necessary for Left Main Coronary Artery PCI?

Percutaneous coronary intervention (PCI) of the unprotected left main coronary artery is a highly complex procedure because of the large amount of myocardium at...

Dual-Prep Registry: Atherectomy and IVL for Severe Coronary Calcification

Severe coronary calcification remains one of the most challenging scenarios in percutaneous coronary intervention (PCI). Although rotational or orbital atherectomy and intravascular lithotripsy (IVL)...