EuroPCR 2023 | ACURATE Neo2: Results After 5 Years

The ACURATE Neo2 valve is an evolution of the first-generation ACURATE Neo valve with a low rate of pacemaker implantation and a decrease in paravalvular leak, also compatible with the 14F introducer.

This prospective study included patients with symptomatic severe aortic stenosis at high surgical risk who underwent ACURATE Neo2 valve implantation.

The primary endpoint (PEP) was all-cause mortality at 30 days. The secondary endpoint (SEP) included procedural and device success, 5-year VARC-2 events, and hemodynamic variables measured by echocardiography at discharge, at 7 days, 30 days, and 1 year.

The study included 120 patients from December 2016 to November 2017. Mean patient age was 82 years old, and most subjects were female. The mean Society of Thoracic Surgeons (STS) score was 4.8%, while the mean EUROSCORE II was 4.7. In terms of the New York Heart Association class, 95% of patients were CF III symptomatic. Basal electrocardiographic alterations were found in 47.5% of subjects, and 6.7% of them had a prior pacemaker.

Procedural success was 97%; the vascular complications rate was 2.5% and the need of pacemaker implantation at discharge was 13%. The most used valve size was M (45%). As regards results, the PEP was 3.3% at 30 days. At 5 years, the all-cause death rate was 44%, the cardiovascular death rate was 31.5%, and the stroke rate was 14.2%. The rate of repeat  procedure after the initial procedure was 1.1%. There was no thrombosis or endocarditis. The rate of hospitalization for valve-related symptoms or heart failure at 5 years was 14.6%.

Read also: EuroPCR 2023 | TAVR in Patients with Bicuspid Aortic Valve Stenosis.

The rate of paravalvular leak at 1 year was, in most cases, no leak (60%) followed by mild leak (37%) and moderate leak (2.7%), and there were no patients with leak greater than moderate.

Conclusion

Patients treated with the ACURATE Neo2 device showed early hemodynamic improvement and low perivalvular leak rates at 1 year. The all-cause mortality and stroke rates at 5 years are comparable with other transcatheter aortic valve replacement studies at intermediate or high surgical risk. This long-term study confirms the favorable performance and safety of the ACURATE Neo2 in high-risk patients.

Dr. Andrés Rodríguez.
Member of the editorial board of SOLACI.org.

Original Title: Five years outcomes with the ACURATE Neo2 valve: The Neo AS CE-mark study.

Reference: H. Mӧllmann.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Embolization of Left Atrial Appendage Closure Devices: Predictors, Prevention, and Management Strategies

Atrial fibrillation is associated with an increased risk of stroke and, in patients with contraindications to anticoagulation, percutaneous left atrial appendage closure represents an...

Coronary revascularization before TAVI: prior PCI or conservative management?

The coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis undergoing TAVI is common, with a reported prevalence ranging from 30%...

Percutaneous Mechanical Aspiration versus Surgical Treatment of Tricuspid Valve Endocarditis

Tricuspid valve infective endocarditis (TVIE) accounts for approximately 5% to 10% of all cases of infective endocarditis. Surgical treatment remains the standard therapy in...

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

ACVC 2026 | CELEBRATE Trial: Prehospital Zalunfiban Use in STEMI

Optimizing antithrombotic therapy in the prehospital phase of ST-segment elevation myocardial infarction (STEMI) remains challenging due to the delayed onset of action of P2Y12...

ACVC 2026 | BOX Substudy: Mean Arterial Pressure Targets in Cardiogenic Shock After OHCA

Hemodynamic management of cardiogenic shock following ischemic out-of-hospital cardiac arrest (OHCA-AMICS) remains an unresolved issue, particularly regarding optimal mean arterial pressure (MAP) targets and...

ACVC 2026 | FLASH Registry European Cohort: Mechanical Thrombectomy in Pulmonary Embolism

The management of intermediate-high and high-risk pulmonary embolism (PE) remains an area of therapeutic uncertainty, particularly in patients with right ventricular (RV) dysfunction, in...