Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

Left Atrial Appendage Closure: Implantation Depth Could Determine Thrombosis Risk

Left atrial appendage closure (LAAC) has undergone significant advances over the past two decades. This progress has been driven by the development of new devices, improved procedural safety, and the growing body of evidence supporting broader clinical adoption. Despite these advances, device-related thrombosis (DRT) remains a major concern because of its association with an increased risk of thromboembolic events. Several risk factors for DRT have been identified, although most are non-modifiable. 

Among the few modifiable factors, deep device implantation has consistently emerged as one of the most significant predictors of DRT across multiple studies. Distal device implants leave a relevant portion of the left atrium exposed to blood stasis around the device surface, potentially promoting thrombus formation.

Recent advances in computational fluid dynamics (CFD) modeling have enabled patient-specific blood flow simulations to assess the risk of device-related thrombosis after LAAC. These simulations have provided valuable insights into the relationship between left atrial appendage anatomy, hemodynamics, and thrombus development. However, previous studies have been limited by small sample sizes, restricting the generalizability of their findings.

The aim of this study was to evaluate the impact of device implantation depth on blood flow dynamics after LAAC using CFD-based simulations and to explore its potential role in DRT risk stratification.

Read also: Influence of cusp-overlap and three-cusp coplanar techniques on new-onset conduction disturbances after TAVI.

The Primary Endpoint (PEP) was to compare CFD-derived flow indices — device surface velocity index (DSVI), endothelial cell activation potential (ECAP), and the presence of vortices/stagnant flow — between proximal and distal implantation groups. The Secondary Endpoint (SEP) was to explore the relationship between these flow characteristics and the rate of DRT.

The study included 285 patients who underwent LAAC with Amplatzer Amulet or WATCHMAN devices across 10 centers. Patient-specific CFD simulations were performed using postprocedural computed tomography and echocardiography to assess blood flow dynamics. The mean age was 75 years, and most patients were male.

Read also: Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak.

Proximal implants (57.2%) demonstrated more favorable flow patterns, including higher DSVI (0.11 m/s vs. 0.09 m/s; p = 0.002), lower ECAP (0.75 vs. 0.90; p = 0.003), and fewer recirculation zones (40.5% vs. 74.6%; p < 0.001). The incidence of DRT increased with greater implantation depth, in parallel with worsening flow indices. A CFD-based DRT risk score incorporating ECAP, implantation depth, and flow complexity showed good discriminatory capacity (ROC area under the curve [AUC] 0.81), outperforming anatomical depth alone (AUC 0.71).

Conclusion: Greater implantation depth after LAAC is associated with abnormal blood flow dynamics and a worse hemodynamic profile

The use of CFD simulations in patients undergoing LAAC demonstrated a clear relationship between deeper distal implantation and abnormal flow patterns associated with a higher risk of device-related thrombosis (DRT). These findings highlight the close relationship between altered blood flow dynamics and thrombus formation.

Título Original: Impact of device implantation depth on blood flow dynamics after left atrial appendage closure.

Referencia: Pedro Cepas-Guillén et al EuroIntervention 2026;22:e444-e454.


Suscríbase a nuestro newsletter semanal

Reciba resúmenes con los últimos artículos científicos

Dr. Andrés Rodríguez
Dr. Andrés Rodríguez
Member of the Editorial Board of solaci.org

More articles by this author

Influence of cusp-overlap and three-cusp coplanar techniques on new-onset conduction disturbances after TAVI

New-onset conduction disturbances remain one of the most frequent complications after transcatheter aortic valve implantation (TAVI), being associated with worse long-term clinical outcomes. Among...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

Beyond TAVI: Cardiac Rehabilitation as a Determinant of Clinical Outcomes

Aortic stenosis is an increasingly prevalent condition associated with population aging, with a prevalence of approximately 3.4% in individuals over 75 years of age...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Influence of cusp-overlap and three-cusp coplanar techniques on new-onset conduction disturbances after TAVI

New-onset conduction disturbances remain one of the most frequent complications after transcatheter aortic valve implantation (TAVI), being associated with worse long-term clinical outcomes. Among...

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity