Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

Are reversal flow cerebral protection devices useful in carotid angioplasty?

Original title: Prospective, Multicenter European Study of the GORE Flor Reversal System for Providing Neuroprotection During Carotid Artery Stenting Reference: Dimitrios Nikas, et, al.Catheterization and Cardiovascular Intervention 80:1060-1068 

Cerebral protection systems (CPS) have proved useful in carotid angioplasty stenting (CAS), although it is not clear what the advantages are in respect to carotid endarterectomy, except in high risk patients, (Pts). 

In the majority of performed studies a CPS filter type was used with no reverse flow systems. The objective was to analyze the results within 30 days of the CAS with a reverse flow system, (GORE Flow Reversal System WL Gore & Associates, Flasgstaff, AZ). Symptomatic Pts who had lesions were included ≥ 50% or asymptomatic with lesion ≥ 70%. Pts with contralateral carotid occlusion, stroke within 14 days or TIA within 48 hours were excluded.

Each surgeon should have conducted at least 10 CAS procedures with the device. All Pts underwent a prior neurological examination performed by an independent neurologist; we used the NIHSS neurological score and CT or MRI before the CAS. Before procedure Pts received ASA and clopidogrel. The primary endpoint was death or stroke within 30 days and the secondary was acute myocardial infarction or neurological events unrelated to stroke. 

We included 122 Pts of which 28% were symptomatic, 26.2% were older than 75 years, 29.5% were diabetic and 8.2% presented renal insufficiency. The choice of stent was at the discretion of the surgeon. The use of the device was successful in 97.5%. Two Pts were intolerant to the device and could not be accessed by major iliac tortuosity. The primary end point within 30 days was 1.6% (two Pts, one had a higher stroke and the other a minor stroke).

Conclusion 

The use of a cerebral protection system, GORE Flow Reversal System, during CAS has a high success rate with low complications within 30 days.

Editorial Comment:

This analysis has limitations due to the lack of randomization, the control group, the small sample and the fact that less than a third of Pts were symptomatic. It is important to remember that surgeons must be experienced in carotid angioplasty and should be familiar with cerebral protection devices. In this study, as in others, we must take into account the limitations of the device prior to its use. It is important to develop new protection devices and stents for better results. 

Courtesy of Carlos Fava, MD.
Interventional Cardiologist
Fundación Favaloro – Argentina

Dr. Carlos Fava para SOLACI.ORG

More articles by this author

SCAI 2026 | Deep vein arterialization as an alternative in patients with critical limb ischemia without conventional options

Critical limb ischemia (CLI) represents one of the most advanced stages of peripheral arterial disease (PAD). In a significant proportion of patients, distal anatomy,...

C-TRACT: Endovascular therapy in post-thrombotic syndrome due to iliac obstruction

Post-thrombotic syndrome (PTS) is one of the most limiting sequelae following proximal deep vein thrombosis (DVT). It clinically manifests as chronic pain, edema, skin...

Coil embolization of segmental arteries as a spinal cord protection strategy prior to complex endovascular repair of thoracoabdominal aorta

Spinal cord ischemia remains one of the most devastating complications in the repair of thoracoabdominal aneurysms, with incidences of up to 20–30% in extensive...

Mechanical thrombectomy versus anticoagulation in intermediate-risk pulmonary embolism: systematic review and meta-analysis

Intermediate-risk pulmonary embolism (PE) has anticoagulation as the standard treatment, while reperfusion strategies remain a matter of debate. In this context, mechanical thrombectomy has...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

KISS Trial: provisional stenting in non-left main coronary bifurcations — is less more?

Coronary bifurcation angioplasty remains one of the most frequent and technically challenging scenarios in interventional cardiology. Between 15% and 20% of coronary procedures involve...

Complex radial access: a four-step protocol to overcome loops and tortuosity

Radial access is currently the preferred strategy for coronary angiography and percutaneous coronary interventions due to its lower rates of bleeding and vascular complications...

Percutaneous closure of paravalvular leaks in high-risk patients: clinical outcomes and the impact of residual leak

Paravalvular leak (PVL) is a relatively frequent complication following valve replacement (overall incidence 5–18%; 2–10% in the aortic position and 7–17% in the mitral...