Evolut R: Clinical Results Might Be Better than Those for First-Generation CoreValve

Evolut R corevalveTwo recent articles featured in  JACC Cardiovascular Interventions  showed that short term (at 30 days) outcomes of patients treated with the next-generation self-expanding Medtronic Evolut R valves could present several advantages compared to the original CoreValve, including recapturability. Both analyses reported similar rates of all-cause mortality and stroke.

 

The study carried out by Dr. Jeffrey Popma as main investigator reported outcomes for 241 patients who were not suitable candidates for surgery (but who could have undergone surgery nevertheless) and were included in the CoreValveEvolut R US Clinical Study registry. At 30 days, the rate of all-cause mortality was 2.5% and the rate of disabling stroke was 3.3%. Life-threatening or major bleeding occurred in 7.1% of patients.

 

In the other published study, Dr. Kalra analyzed 264 real-world consecutive patients participating in the UK and Ireland registry. As regards outcomes, the rate of all-cause mortality at 30 days was 2.3% and the rate of stroke was 3.8% (all non-disabling).

 

In the UK registry, the rate of pacemaker implantation was 14.7%, and the device was implanted a mean of 3 days after the procedure. In the US trial, the rate of pacemaker implantation was 16.4%.

 

The most notorious difference between these studies was related to the rates of paravalvular leak, for which one of the studies reported moderate or severe leak in 7.7% of patients and, in the other, the rate was lower (5.3%), all leaks were moderate, and no severe cases were reported.

 

The next-generation CoreValve device, called Evolut R, is a recapturable and repositionable valve implanted through a delivery system of only 14-F.

 

In the European registry, the average age of patients was 81 years old and the EuroSCORE was 19.9. Approximately 40% of patients received a valve without general anesthesia and only sedation. This is in agreement with the worldwide minimalistic trend in this regard.

 

Both studies reported a low rate of vascular complications (between 5% and 7%), as expected from a 14-F device.

 

The rate of pacemaker implantation with first-generation CoreValve devices of around 25% was clearly improved with Evolut R, bringing this valve much closer to results observed with the balloon-expandable valve.

 

While these outcomes for Evolut R have been recently published, a newer next-generation device, called Evolut R PRO, is already available in some places. This device features a porcine pericardial skirt aimed at reducing the rate of paravalvular leak.

 

Original title: Early Clinical Outcomes AfterTranscatheter Aortic Valve Replacement Using a Novel Self-Expanding Bioprosthesis in Patients with Severe Aortic Stenosis Who Are Suboptimal for Surgery.

Reference: PopmaJJ et al. J Am CardiolIntv 2017;10:268-275 y Kalra SS et al. J Am CardiolIntv 2017;10:276-282.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

Coronary revascularization before TAVI: prior PCI or conservative management?

The coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis undergoing TAVI is common, with a reported prevalence ranging from 30%...

Percutaneous Mechanical Aspiration versus Surgical Treatment of Tricuspid Valve Endocarditis

Tricuspid valve infective endocarditis (TVIE) accounts for approximately 5% to 10% of all cases of infective endocarditis. Surgical treatment remains the standard therapy in...

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Drugs for the Treatment of No-Reflow During PCI

The no-reflow phenomenon is one of the most frustrating complications of primary angioplasty (pPCI), reflecting persistent microvascular damage that, in the mid- to long-term,...

Coronary revascularization before TAVI: prior PCI or conservative management?

The coexistence of coronary artery disease (CAD) in patients with severe aortic stenosis undergoing TAVI is common, with a reported prevalence ranging from 30%...

Rotational atherectomy and its technical secrets: use of floppy or ES guidewire

Rotational atherectomy (RA) remains a very useful tool in the management of severe coronary calcification. However, many of its technical aspects rely more on...