DESolve I FIM: Evaluation of a FIM trial results of a bioabsorbable stent (15 patients).

This trial is a prospective evaluation of DESolveTM bioabsorbable coronary stent implantation in a 15 patient cohort enrolled in New Zealand and Belgium. At 6 months follow up, late lumen loss was 0,19 mm, binary restenosis was 0% and thrombosis was absent. OCT evaluation showed excellent stent apposition, and 98% of evaluated struts were covered with a thin neointimal layer. Neointimal obstruction percentage was 7,1%.

According to Dr. Verheye, preclinical evaluation showed excellent results with a low percentage of acute recoil or scaffold shrinkage (6%), which shows great radial strength. This stent is reabsorbed in 1-2 years. This device is available in a broad range of sizes and has some features that make them particularly interesting, such as their capacity to limit malapposition and their resistance to fracture. Preliminary clinical outcomes suggest a promising future due to its potent antiproliferative effect and its adequate reendothelization. In view of these results, the DESolveTM Nx Pivotal Trial (n=120) has started enrolling in Europe, New Zealand and Brazil.

verheye-desolve-fim-16-may
Stefan Verheye
2012-05-16

Mais artigos deste autor

DISCOVER FLOW: Correlação FFR convencional em contraste com FFR não invasiva obtida por MSCT para o implante correto de stents.

Recentemente, o estudo DISCOVER FLOW demostrou uma excelente correlação entre os valores de reserva fracionada de fluxo (FFR) obtidos de forma tradicional e os...

CLI-OPCI: Implante de stent guiado por OCT em contraste com Angioplastia convencional guiada por angiografia.

O estudo randomizado CLI-OPCI (n=670, 1:1) avaliou o impacto de guiar o implante de stent com angiografia e tomografia de coerência óptica (optical coherence...

TROFI: Comparação de área mínima de fluxo intrastent em Angioplastia Primária com e sem Tromboaspiração Manual.

O Dr. P. Serruys apresentou os resultados do Estudo TROFI no qual foi comparada a área mínima de fluxo intrastent (AMFI) em pacientes com...

SMART: Tromboaspiración Manual vs Aspiración Reolítica en el Infarto Agudo de Miocardio con Supradesnivel del Segmento ST.

El Dr. David Antoniucci presento los resultados inmediatos del estudio randomizado SMART (n=80, 1:1) que comparó tromboaspiración manual (TM) versus Aspiración Reolítica (AR) en...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Artigos Relacionados

Congressos SOLACIspot_img

Artigos Recentes

Eventos em acompanhamento de um ano do registro do sistema bicava TricValve para insuficiência tricúspide severa

O TricValve é o primeiro dispositivo de implante na cava que obteve a aprovação CE-Mark. Trata-se de um dispositivo heterotópico que elimina o refluxo...

Resultados a longo prazo do Registro internacional de Chaminés (Chimney Registry)

O registro internacional Chimney (ou Chaminés) foi um estudo observacional dedicado a avaliar o uso do chimney stenting durante o procedimento de TAVI, tanto...

CANNULATE TAVR extended study: Impacto do alinhamento comissural e coronariano na canulação das coronárias após o TAVI com Evolut Fx

A nova válvula Evolut FX demonstrou um melhor alinhamento comissural em comparação com sua predecessora, a Evolut Pro+. Estudos prévios já tinham evidenciado que...