DESolve I FIM: Evaluation of a FIM trial results of a bioabsorbable stent (15 patients).

This trial is a prospective evaluation of DESolveTM bioabsorbable coronary stent implantation in a 15 patient cohort enrolled in New Zealand and Belgium. At 6 months follow up, late lumen loss was 0,19 mm, binary restenosis was 0% and thrombosis was absent. OCT evaluation showed excellent stent apposition, and 98% of evaluated struts were covered with a thin neointimal layer. Neointimal obstruction percentage was 7,1%.

According to Dr. Verheye, preclinical evaluation showed excellent results with a low percentage of acute recoil or scaffold shrinkage (6%), which shows great radial strength. This stent is reabsorbed in 1-2 years. This device is available in a broad range of sizes and has some features that make them particularly interesting, such as their capacity to limit malapposition and their resistance to fracture. Preliminary clinical outcomes suggest a promising future due to its potent antiproliferative effect and its adequate reendothelization. In view of these results, the DESolveTM Nx Pivotal Trial (n=120) has started enrolling in Europe, New Zealand and Brazil.


Stefan Verheye
2012-05-16

Mais artigos deste autor

DISCOVER FLOW: Correlação FFR convencional em contraste com FFR não invasiva obtida por MSCT para o implante correto de stents.

Recentemente, o estudo DISCOVER FLOW demostrou uma excelente correlação entre os valores de reserva fracionada de fluxo (FFR) obtidos de forma tradicional e os...

CLI-OPCI: Implante de stent guiado por OCT em contraste com Angioplastia convencional guiada por angiografia.

O estudo randomizado CLI-OPCI (n=670, 1:1) avaliou o impacto de guiar o implante de stent com angiografia e tomografia de coerência óptica (optical coherence...

TROFI: Comparação de área mínima de fluxo intrastent em Angioplastia Primária com e sem Tromboaspiração Manual.

O Dr. P. Serruys apresentou os resultados do Estudo TROFI no qual foi comparada a área mínima de fluxo intrastent (AMFI) em pacientes com...

SMART: Tromboaspiración Manual vs Aspiración Reolítica en el Infarto Agudo de Miocardio con Supradesnivel del Segmento ST.

El Dr. David Antoniucci presento los resultados inmediatos del estudio randomizado SMART (n=80, 1:1) que comparó tromboaspiración manual (TM) versus Aspiración Reolítica (AR) en...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Artigos Relacionados

Congressos SOLACIspot_img

Artigos Recentes

Técnica UNICORN para prevenir a obstrução coronariana durante o TAVI: resultados iniciais de um estudo multicêntrico

A obstrução coronariana é uma complicação pouco frequente, mas potencialmente catastrófica, do implante transcateter da valva aórtica (TAVI), especialmente em procedimentos valve-in-valve, TAV-in-TAV ou...

Espaço do Fellow – Caso 2: Infarto Agudo do Miocárdio por Oclusão Simultânea de Duas Artérias Coronárias

Compartilhe sua experiência. Aprenda com especialistas. Cresça como intervencionista. Chega uma nova edição do Cantinho do Fellow, um espaço de intercâmbio acadêmico criado para que...

Supera vs. Eluvia em lesões femorpoplíteas calcificadas com calcificação severa

A calcificação seveera continua sendo um dos principais preditores de reestenose e de necessidade de novas revascularizações após o tratamento endovascular da doença femoropoplítea....