Modelos europeos de telemedicina, como el servicio finlandés Medilux, permiten realizar consultas médicas online mediante un cuestionario clínico, sin acudir a una consulta presencial.

Everolimus-Eluting Stents Finally Have a Rival and Not Just a “Non-Inferior” Stent

In this large randomized trial, there were significant differences as regards both target-lesion failure and target-vessel-related infarction, which persisted through a 2-year follow-up and favored treatment with an ultrathin-strut bioresorbable-polymer sirolimus-eluting stent (Orsiro) compared with the gold standard, a durable-polymer everolimus-eluting stent (Xience).

BVS_everolimus-compressorMoreover, there were significantly lower rates of target lesion revascularization and late/very late stent thrombosis (which already were extremely low with Xience).

 

This study sought to compare long-term clinical events with an ultrathin-strut (60 µm) bioresorbable-polymer sirolimus-eluting stent vs. a thin-strut (81 µm) durable-polymer everolimus-eluting stent.

 

BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness ofthe Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or RestenoticCoronary Artery Lesions V) was an international randomized trial comparing both devices regarding the primary endpoint of 12-month target lesion failure. It already included an analysis of pre-specified 2-year clinical events.


Read also: Balloon-Expandable vs. Self-Expanding: To Each Valve Its Own Annulus.


A total of 1334 patients were randomized; 884 received Orsiro and 450 received Xience. The primary endpoint (target-lesion failure) was 7.5% for Orsiro and 11.9% for Xience (p = 0.015), basically driven by a wide difference in the rate of target-vessel-related infarction (5.3% vs. 9.5%; p = 0.01) and ischemia-driven revascularization (2.6% vs. 4.9%; p = 0.04).

 

The rates of death and infarction were 7% vs. 10.4% (p = 0.047), always favoring Orsiro.

 

Late/very late definite thrombosis was also lower with the new device (p = 0.045).


Read also: Vascular Surgeons of the Future in the Endovascular Era.


Given prior evidence, these differences seem to derive from strut width (60 µm vs. 81 µm), as opposed to the drug or the polymer. This appears to be the way for new stents to overcome the plateau where we have spent these last years.

 

Original title: Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents. The BIOFLOW V Investigators.

Reference: David E. Kandzari et al. J Am Coll Cardiol 2018;72:3287-97.

 

struts-ultrafinos.full


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

SCAI 2026 | SELUTION DeNovo subanalysis: Use of sirolimus-eluting balloon in acute coronary syndrome

Percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation remains the predominant strategy in the setting of acute coronary syndrome (ACS). However, in recent...

Calcified Nodules and Their Treatment with Rotational Atherectomy

Calcified nodules (CN) represent one of the most complex phenotypes to treat in coronary intervention. They are mainly associated with the need for repeat...

Complex PCI: higher ischemic and bleeding risk in contemporary practice

Advances in pharmacological therapies, equipment, and devices have enabled percutaneous coronary interventions (PCI) to be performed in a growing number of patients with a...

High Ischaemic Risk Criteria in Chronic Coronary Syndrome: Prevalence and Prognosis

Despite advances in the management of chronic coronary syndrome (CCS), including the widespread use of drug-eluting stents (DES) and the optimization of medical therapy,...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

SCAI 2026 | Deep vein arterialization as an alternative in patients with critical limb ischemia without conventional options

Critical limb ischemia (CLI) represents one of the most advanced stages of peripheral arterial disease (PAD). In a significant proportion of patients, distal anatomy,...

SCAI 2026 | Can an atrial fixation device prevent complications of transcatheter mitral valve replacement? Analysis of the AltaValve system

Transcatheter mitral valve replacement (TMVR) represents one of the most complex areas within structural interventions. Unlike TAVI, where valvular anatomy typically provides more predictable...

SCAI 2026 | SELUTION DeNovo subanalysis: Use of sirolimus-eluting balloon in acute coronary syndrome

Percutaneous coronary intervention (PCI) with drug-eluting stent (DES) implantation remains the predominant strategy in the setting of acute coronary syndrome (ACS). However, in recent...