Everolimus-Eluting Stents Finally Have a Rival and Not Just a “Non-Inferior” Stent

In this large randomized trial, there were significant differences as regards both target-lesion failure and target-vessel-related infarction, which persisted through a 2-year follow-up and favored treatment with an ultrathin-strut bioresorbable-polymer sirolimus-eluting stent (Orsiro) compared with the gold standard, a durable-polymer everolimus-eluting stent (Xience).

BVS_everolimus-compressorMoreover, there were significantly lower rates of target lesion revascularization and late/very late stent thrombosis (which already were extremely low with Xience).

 

This study sought to compare long-term clinical events with an ultrathin-strut (60 µm) bioresorbable-polymer sirolimus-eluting stent vs. a thin-strut (81 µm) durable-polymer everolimus-eluting stent.

 

BIOFLOW V (Biotronik Prospective Randomized Multicenter Study to Assess the Safety and Effectiveness ofthe Orsiro Sirolimus Eluting Coronary Stent System in the Treatment of Subjects with Up to Three De Novo or RestenoticCoronary Artery Lesions V) was an international randomized trial comparing both devices regarding the primary endpoint of 12-month target lesion failure. It already included an analysis of pre-specified 2-year clinical events.


Read also: Balloon-Expandable vs. Self-Expanding: To Each Valve Its Own Annulus.


A total of 1334 patients were randomized; 884 received Orsiro and 450 received Xience. The primary endpoint (target-lesion failure) was 7.5% for Orsiro and 11.9% for Xience (p = 0.015), basically driven by a wide difference in the rate of target-vessel-related infarction (5.3% vs. 9.5%; p = 0.01) and ischemia-driven revascularization (2.6% vs. 4.9%; p = 0.04).

 

The rates of death and infarction were 7% vs. 10.4% (p = 0.047), always favoring Orsiro.

 

Late/very late definite thrombosis was also lower with the new device (p = 0.045).


Read also: Vascular Surgeons of the Future in the Endovascular Era.


Given prior evidence, these differences seem to derive from strut width (60 µm vs. 81 µm), as opposed to the drug or the polymer. This appears to be the way for new stents to overcome the plateau where we have spent these last years.

 

Original title: Ultrathin Bioresorbable Polymer Sirolimus-Eluting Stents Versus Thin Durable Polymer Everolimus-Eluting Stents. The BIOFLOW V Investigators.

Reference: David E. Kandzari et al. J Am Coll Cardiol 2018;72:3287-97.

 

struts-ultrafinos.full


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

We are interested in your opinion. Please, leave your comments, thoughts, questions, etc., below. They will be most welcome.

More articles by this author

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...

CRT 2026 | Clopidogrel vs Aspirin as Long-Term Monotherapy After Coronary Angioplasty

The use of aspirin as chronic antiplatelet therapy after percutaneous coronary intervention (PCI) has historically been the standard recommended by international guidelines. However, recent...

Bioresorbable devices vs DES in patients at high risk of restenosis. Seven-year follow-up of the COMPARE-ABSORB trial

Studies with second-generation drug-eluting stents (DES) have shown that the rate of target lesion failure (TLF) increases linearly up to 5–10 years of follow-up,...

Sheathless Femoral Impella: A New Strategy to Reduce Vascular Complications in High-Risk PCI?

Patients with complex coronary artery disease or cardiogenic shock undergoing percutaneous coronary intervention (PCI) may benefit from the hemodynamic support provided by percutaneous ventricular...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

CRT 2026 | TAVI-CLOSE Trial: Dual Suture vs Suture + Plug for Vascular Closure After Transfemoral TAVI

The transfemoral approach is the predominant strategy for transcatheter aortic valve implantation (TAVI). Although vascular complications are currently less frequent, they remain relevant determinants...

CRT 2026 | NAVITOR IDE: Hemodynamic Outcomes and 5-Year Durability of an Intra-Annular Self-Expanding Transcatheter Aortic Valve

As TAVI expands into younger populations and patients with lower surgical risk, prosthesis durability has become a key aspect of long-term management. The NAVITOR...

CRT 2026 | CUT-DRESS Trial: Lesion Preparation with Cutting Balloon

In-stent restenosis (ISR) continues to represent a relevant clinical challenge in contemporary coronary angioplasty practice. Despite advances in drug-eluting stents, neointimal hyperplasia and suboptimal...