Balloon-Expandable Valve Outdoes Itself

The objective of this paper recently published in J Am Coll Cardiol Intv was to compare the outcomes of transcatheter aortic valve replacement (TAVR) with the new Sapien 3 Ultra vs. Sapien 3.

La válvula balón expandible se supera a sí misma

Successful implantation was extremely high with both balloon-expandable devices, which also had a very low adverse event rates. However, Sapien Ultra was significantly better than Sapien 3 in terms of paravalvular leak.

Both valves are made of bovine pericardium, with a cobalt-chromium stent plus a low-profile delivery system and high radial force. Sapien Ultra additionally has a polyethylene external skirt, which increases the device height by 40%, providing a 50% bigger contact surface with the native valve so as to improve annular sealing. The release system features differences too.

This registry included all consecutive patients who underwent TAVR with Sapien 3 and Sapien Ultra between 2014 and 2020. Propensity score matching was used to compare both arms.

A total of 310 matched patients were included (155 for each device). After propensity score matching, no difference was detected in baseline clinic characteristics.


Read also: Low-Carb Diet and Coronary Artery Calcium Progression.


Procedures were more frequently done under conscious sedation with Sapien Ultra (97.4% vs. 71.6%; p < 0.001) and pre-dilation was significantly less (42.6% vs. 85.2%; p < 0.001).

In-hospital results, including implantation success (91.6% vs. 95.5%; p = 0.165), major vascular complications (12.3% vs. 11.0%; p = 0.723), and pacemaker implantation (5.8% vs. 4.5%; = 0.608) were comparable between Sapien 3 and Ultra, respectively. 

The postprocedural gradient was similar (13.2 ± 5.7 mmHg vs. 13.1 ± 4.7 mmHg; = 0.829) and so were the rates for moderate and higher paravalvular leak (1.3% vs. 2.7%; p = 0.414).


Read also: AHA 2020 | Post-TAVR Anticoagulation in Patients with Atrial Fibrillation.


The significant difference in favor of Sapien Ultra was in mild leak with a rate that was less than half the rate for Sapien 3 (18.7% vs. 43%; p < 0.001).

Conclusion

With excellent results in both devices, adding a polyethylene skirt in the Sapien Ultra device managed to reduce the rate of mild paravalvular leak to less than half.

j-jcin-2020-07-013

Original Title: Transcatheter Aortic Valve Replacement With Balloon-Expandable Valves Comparison of SAPIEN 3 Ultra Versus SAPIEN 3.

Reference: Tobias Rheude et al. J Am Coll Cardiol Intv 2020;13:2631–8. https://doi.org/10.1016/j.jcin.2020.07.013.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Transradial Aortic Valvuloplasty: Is Minimalism Worth It?

Balloon aortic valvuloplasty (BAV) has historically been used either as a bridge strategy, an assessment tool, or even palliative treatment in severe aortic stenosis...

Atrial Fibrillation After Percutaneous Patent Foramen Ovale Closure: Cohort Study with Continuous Implantable Cardiac Monitoring

Atrial fibrillation (AF) is a recognized complication following percutaneous closure of a patent foramen ovale (PFO), with reported incidences of up to 30% during...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img

Recent Articles

Coronary Perforations and Use of Covered Stents: Safe and Effective Long-Term Strategy?

Coronary perforations remain one of the most serious complications of percutaneous coronary intervention (PCI), especially in cases of Ellis ruptures type III. In these...

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....

Is it really necessary to monitor all patients after TAVR?

Conduction disorders (CD) after transcatheter aortic valve replacement (TAVR) are a frequent complication and may lead to the need for permanent pacemaker implantation (PPI)....