EuroPCR 2026 | Coronary bioadaptor: fewer events regardless of IVUS or FFR guidance

Despite the increasing use of intracoronary imaging and physiology, stent-related events continue to occur at an annual rate of approximately 2–3% beyond the first year after PCI. In this context, the DynamX system emerged as a coronary bioadaptor designed to provide initial vessel support and subsequently restore part of the vessel’s physiological function.

The device features a metallic helical structure connected by a bioabsorbable polymer that, after approximately 6 months, partially releases its components, allowing restoration of pulsatility, conformability, and adaptive vascular remodeling. This subanalysis of the INFINITY-SWEDEHEART trial evaluated whether the clinical benefit of the bioadaptor was maintained regardless of the use of intracoronary imaging (IVUS/OCT) or coronary physiology (FFR/iFR).

The primary endpoint was Target Lesion Failure (TLF) between 6 and 24 months, assessing superiority compared with a contemporary DES. Results were analyzed according to the guidance strategy used: intracoronary imaging/physiology versus conventional angiography.

The INFINITY-SWEDEHEART trial included 2,400 patients across 20 centers in Sweden, randomized 1:1 to the DynamX bioadaptor (1,201 patients) or Resolute Onyx DES (1,198 patients). Approximately 25% of procedures were guided by IVUS/OCT or coronary physiology, while the remaining 75% were performed using angiography alone. The population represented a complex clinical setting, with a high prevalence of acute coronary syndrome, long lesions, and complex B2/C lesions. Clinical follow-up at 2 years reached 100%.

Read also: EuroPCR 2026 | Restoring vascular physiology: 4-year results of the BIOADAPTOR-RCT.

In the overall analysis, the bioadaptor demonstrated a significant reduction in TLF between 6 months and 2 years compared with the contemporary DES (1.5% vs 2.8%; p=0.0245). The benefit was observed both in image/physiology-guided procedures and in those guided exclusively by angiography. In the intracoronary guidance group, TLF rates were 1.0% with the bioadaptor versus 2.5% with DES, while in angiography-guided procedures, rates were 1.6% versus 2.9%, respectively. No significant interaction was observed between the type of guidance used and the device effect.

The authors also highlighted that the lower event rates became evident after 6 months, coinciding with the time when the device acquires its dynamic behavior following polymer resorption. Additionally, the use of IVUS/OCT or coronary physiology showed a trend toward lower TLF, in line with current European guideline recommendations for complex PCI.

Conclusion: The DynamX bioadaptor reduced target lesion failure regardless of IVUS or FFR guidance

This subanalysis of the INFINITY-SWEDEHEART trial demonstrated that the DynamX coronary bioadaptor was associated with lower rates of target lesion failure compared with a contemporary DES, regardless of the use of intracoronary imaging or coronary physiology.

Original Title: Impact of Imaging- or Physiology-Guided Coronary Revascularization on Long Term Outcomes with Bioadaptor Implant: Insights from the INFINITY-SWEDEHEART Trial.

Reference: Presentado por David Erlinge en EuroPCR 2026.


Subscribe to our weekly newsletter

Get the latest scientific articles on interventional cardiology

More articles by this author

Plaque Ruptures in Non-Culprit Arteries: Follow-Up With Intravascular Imaging

Plaque rupture remains one of the most important pathophysiological mechanisms in acute coronary syndromes. However, not all ruptures manifest clinically as ischemia, myocardial infarction,...

OCT-Detected High-Risk Plaques Predict Recurrent Events After Myocardial Infarction

After a myocardial infarction (MI), non-culprit lesions are often deferred when they are not flow-limiting (negative FFR). However, these lesions continue to represent an...

Ticagrelor vs Clopidogrel in ACS Patients Receiving DOAC After PCI: More Bleeding Without Ischemic Benefit?

In patients with acute coronary syndrome (ACS) who require direct oral anticoagulation (DOAC) and undergo percutaneous coronary intervention (PCI), current guidelines recommend a dual...

EuroPCR 2026 | 10-Year Left Main PCI: When Survival Is Similar, Should the Less Invasive Strategy Prevail?

The primary goal of revascularization in left main coronary artery disease (LMCA) is to improve survival. However, debate continues regarding whether, in anatomically suitable...

LEAVE A REPLY

Please enter your comment!
Please enter your name here

Related Articles

SOLACI Sessionsspot_img
Jornadas Guatemala 2026

Recent Articles

Plaque Ruptures in Non-Culprit Arteries: Follow-Up With Intravascular Imaging

Plaque rupture remains one of the most important pathophysiological mechanisms in acute coronary syndromes. However, not all ruptures manifest clinically as ischemia, myocardial infarction,...

Drug-Eluting Stents in Peripheral Arterial Disease: When Should They Be Used?

Peripheral drug-eluting stents have transformed the treatment of peripheral arterial disease by reducing restenosis rates and the need for repeat interventions. However, the emergence...

OCT-Detected High-Risk Plaques Predict Recurrent Events After Myocardial Infarction

After a myocardial infarction (MI), non-culprit lesions are often deferred when they are not flow-limiting (negative FFR). However, these lesions continue to represent an...