paravalvular leak

PARTNER 2A: TAVI Not Inferior to Surgery in Intermediate Risk Patients

Transcatheter aortic valve replacement (TAVI) with the new generation balloon expandable valve is at least as good as surgery in intermediate risk patients with severe symptomatic aortic stenosis. For those that can be accessedfemorally, TAVI seems even better than surgery. In all, 2032 intermediate risk patients were randomized in 57 centers to TAVI with Sapien...

The SAPIEN 3 Valve Resulted Superior to Surgery in an Observational Study

The last generation of the balloon expandable valve resulted superior to surgery in intermediate riskpatients, in a registry analyzis. Patients treated with the SAPIEN 3 valve showed lower rates of death, stroke and paravalvular leak at one year than patients undergoing surgery. This third generation improves the SAPIEN XT with a skirt designed to prevent...

PARTNER 1 in +90 Year Old Patients: TAVI and the Age Paradox

A new analyzis of the PARTNER 1 trial showed that patients over 90 undergoing transcatheter aortic valve replacement (TAVI) show no increase in mortality or major cardiovascular events rates, compared to younger patients. In fact, patients over 90 undergoing TAVI have the same life expectation of someone the same age with no aortic stenosis. In-hospital...

SOLACI – SCAI Joint Symposia

We invite you to the SOLACI@SCAI Joint Symposia to be held during the next SOLACI Sessions | April 6 thru 8, 2016 in La Habana, Cuba. Venue: Palace of Congress – La Habana – Cuba Date: Friday, April 8, 2016 Time: 11:15 AM- 12:30 PM Program Co-Chairmen: Dr. Mauricio Cohen (United States) – Dr. Jorge...

PARTNER cohort B: Clinical events at 3 years follow-up in patients with

Background: Percutaneous aortic valve implantation (TAVI) is the treatment of choice for patients with severe aortic stenosis considered inoperable according to clinical outcomes at 12 months as reported in the PARTNER study, which demonstrated a reduction in mortality and an improvement in the quality of life for patients. However, the long term benefit of this...

Incidence and clinical impact of post TAVI infective endocarditis

Original title: Incidence and clinical impact of infective endocarditis after transcatheter aortic valve implantation. Reference: Manuel Martínez-Sellés et al.  EuroIntervention 2015;10-online publish-ahead-of-print February 2015. Prosthesis endocarditis is a complication with serious clinical consequences due to its high morbimortality. Infective endocarditis (IE) in TAVI has been described in few cases and, in cohort studies, it occurs within 0 to...

TAVR minimally invasive, shorter hospital stay and costs without compromising safety or efficacy

Original title: Comparison of Transfemoral TranscatheterAortic Valve Replacement Performedin the Catheterization Laboratory(Minimalist Approach) Versus HybridOperating Room (Standard Approach). Outcomes and CostAnalysis. Reference: VasilisBabaliaros et al. J Am CollCardiolIntv 2014;7:898–904. This retrospective study of a center analyzed the results of percutaneous aortic valve replacement (TAVR) performed with a minimally invasive technique that included the closure of the femoral access...

Last articles on TAVR

The latest scientific articles on TAVI published on our website

01- TAVR and Anticoagulation: Direct Anticoagulant Agents or Vitamin K Inhibitors? In some patients, using an anticoagulant agent is not an option, it is just prescribed. Based on the French TAVR registry, this research compared long-term mortality, bleeding, and ischemic events after valve implantation. A comparison was made between TAVR and direct vs. classic anticoagulant agents—good old proven and reversible vitamin K inhibitors. Read also HERE 02-...

Cirugía para mejorar la sobrevida en insuficiencia tricuspidea aislada

Cusp Overlap for Higher CoreValve Implantation

Implant depth greater than the length of the membranous septum is an independent predictor of permanent pacemaker implantation. Valve implantation 3 to 5 mm below the aortic annulus in a projection coaxial to the device is recommended. The problem is this is rarely in the annular plane of the valve. Ideal annular plane projection is...

Top