DES

angioplastia_compleja_octogenario

OCT Provides Hints About the Physiopathology Behind Very Late Stent Thrombosis

Neoatherosclerosis was frequently observed in patients who experienced very late stent thrombosis, particularly those with drug-eluting stents. In-stent plaque rupture was the most common cause of thrombosis and it usually occurred in cases in which the original procedure had been carried out while the patient was undergoing an acute myocardial infarction. Macrophage infiltration can be...

DES de 2.0 mm para vasos muy pequeños: ¿Es viable?

New Ultra-Thin-Strut DES: Do They Outperform Second-Generation DES?

The new drug-eluting stents (DES) equipped with ultra-thin struts are showing a lower risk of target lesion failure as a result of lower rates of acute myocardial infarction and similar rates of revascularization, according to this meta-analysis soon to be published in Circulation. Such a difference is evidenced at a 1-year follow-up when compared with...

DES de 2° vs 3° generación en bifurcaciones: nada nuevo bajo el sol

EuroPCR 2018 | 2nd and 3rd-Generation DES for Bifurcation Lesions: Nothing New Under the Sun

This study aimed to assess the outcome of Culotte stenting with newer-generation drug-eluting stents (DES) in Medina 1, 1, 1 bifurcation lesions. The 2nd-generation device used was permanent-polymer everolimus-eluting stent Xience, a device for which there is comparatively plenty of evidence available. Alternatively, the 3rd-generation stent used was thin-strut abluminal bioresorbable-polymer everolimus-eluting stent SYNERGY. Patients with...

EuroPCR 2018 | DESSOLV III: polímero bioabsorbible vs durable a 2 años

EuroPCR 2018 | DESSOLV III: Bioabsorbable vs. Durable Polymer at 2 Years

Most drug-eluting stents are coated by a polymer that is used to contain the antiproliferative drug. Once the drug is released, the polymer remains in place and its presence has been associated with inflammation, restenosis, and neoatherosclerosis. The MiStent device features a polymer that becomes bioabsorbable once the drug has been released, which could, theoretically,...

Registro Sueco con stent SYNERGY: por primera vez stent probado en angioplastia primaria

EuroPCR 2018 | Swedish Registry on the SYNERGY DES: tested in primary PCI for the first time

The study included 36292 consecutive patients undergoing acute myocardial infarction receiving PCI with the new generation stent SYNERGY (thin struts, bioresorbable polymer and everolimus eluting); 39.7% presented ST elevation MI. Kaplan-Meier curves at 2 years of patients receiving the SYNERGY vs patients receiving other drug eluting stents resulted very similar for thrombosis (0,69% vs 0,81%,...

BIO-RESORT: polímeros vs polímeros bioabsorbibles ¿Llegamos a una meseta con los DES?

EuroPCR 2018 | BIO-RESORT: Polymer vs. Bioresorbable Polymer; Have We Reached a Plateau with DES?

This study randomized 3514 patients to a thin-strut biodegradable polymer everolimus-eluting stent (SYNERGY) vs. a sirolimus-eluting stent (ORSIRO) vs. a durable polymer zotarolimus-eluting stent (RESOLUTE INTEGRITY). The combined endpoint, the rate of target vessel failure, was similar for all three devices (8.3% for the zotarolimos-eluting stent, 6.8% for the everolimus-eluting stent, and 6.6% for the sirolimus-eluting...

The new HTA guides 2017 could be up to their predecessors

From the first reports, back in 1920, we have studied, recognized and documented the excess of events associated with arterial hypertension. This linear relationship between the level of blood pressure and the risk of stroke, is evident in all adults beyond age, sex or race, transforming high blood pressure into the highest target of global...

Top