Controlling stent expansion with optical coherence tomography (OCT) based on an external elastic membrane–based protocol for stent sizing resulted non-inferior to the control group which used intravascular ultrasound (IVUS) and superior the angiography only group. Based on these study outcomes and the prior outcomes, we should use IVUS imaging if available. There are no specific algorithms…