tavr

PARTNER cohort B: 5-year results of a balloon-expandable valve on inoperable patients

This study included 358 patients considered inoperable, randomized to TAVR with expandable balloon valve versus conservative treatment. The 5-year end points included all-cause mortality, cardiac mortality, re-hospitalization, and stroke. At 5 years, mortality from all causes was lower in TAVR group versus conservative treatment group (71.8% versus 93.6%, P <0.0001). By dividing patients by STS...

CLEAN-TAVI: transcatheter aortic valve replacement with cerebral protection

The stroke is a leading complication of post transcatheter aortic valve implantation increasing up to 3 times the mortality of these patients. In the works performed neuroimaging new post, TAVR defects were observed in two-thirds of patients and this increases the risk of post clinical stroke.  There is a missing data in the literature of...

PARTNER cohort B: Clinical events at 3 years follow-up in patients with

Background: Percutaneous aortic valve implantation (TAVI) is the treatment of choice for patients with severe aortic stenosis considered inoperable according to clinical outcomes at 12 months as reported in the PARTNER study, which demonstrated a reduction in mortality and an improvement in the quality of life for patients. However, the long term benefit of this...

Educational Journal N° 98

1. ESTUDIOS DE TECNOLOGIAS EN INTERVENCIONES CORONARIAS • RIBS IV – Presentador: Fernando Alfonso • ABSORB II – Presentador: Patrick Serruys 2. ESTUDIOS DE FARMACOLOGIA EN INTERVENCIONES CORONARIAS • ISAR-TRIPLE – Presentador: Nikolaus Sarafoff • SECURITY – Presentador: Antonio Colombo • BRIGHT – Presentador: Yalin Hang 3. ESTUDIOS EN IMÁGENES CORONARIAS • IVUS-CTO – Presentador:...

Results of the new repositionable and retrievable percutaneous valve system

Original title: Transcatheter Aortic Valve Replacement for Severe Symptomatic Aortic Stenosis Using a Repositionable Valve System. 30-Day Primary Endpoint Results From the REPRISE II Study. Reference: Ian T. Meredith AM et al. J Am Coll Cardiol 2014;64:1339–48. Transcatheter aortic valve replacement (TAVR) showed results comparable to those of surgery in patients at high surgical risk, but complications can...

Stress echocardiography in low flow, low gradient aortic stenosis with deteriorated systolic function

Echocardiography  Favaloro Foundation. Buenos Aires, Argentina. JACC Cardiovascular Imaging has recently published a retrospective analysis including severe aortic stenosis patients (< 1 cm²), with low gradient (mean aortic gradient Patients that had undergone dobutamine stress echocardiography (DSE) to distinguish pseudo aortic stenosis (n=49) were selected. These results were used to determine flow reserve (FR). The...

The delay between the indication and the embodiment of the procedure decrease the effectiveness of percutaneous aortic valve replacement

Original title: Impact of wait times on the effectiveness of transcatheter aortic-valve replacement (TAVR) in severe aortic valve disease: a discrete event simulation model. Reference: Wijeysundera HC et al. Can J Cardiol. 2014; Epub ahead of print. Once patients are accepted for percutaneous aortic valve replacement (TAVR), the higher the expected for the valve, the greater the risk...

Top