revascularization

TCT 2017 | ORBITA: el efecto placebo de la angioplastia

TCT 2017 | ORBITA: The Placebo Effect of Angioplasty

Courtesy of the SBHCI. Chronic stable angina and severe coronary lesion patients who undergo angioplasty in a single vessel show no better outcomes than individuals who undergo a placebo sham procedure when it comes to exercise capacity and symptoms, according to this study presented at TCT and published simultaneously in the Lancet. The curious results...

TCT 2017 | SENIOR: DES con polímero reabsorbible y tiempo de doble antiagregación corto en pacientes añosos

TCT 2017 | SENIOR: DES with a Bioresorbable Polymer and Short Dual Antiplatelet Therapy in Elderly Patients

 Courtesy of the SBHCI. This study sought to assess the safety and efficacy of an everolimus-eluting stent with a biodegradable polymer (SYNERGY II) vs. a conventional stent (REBEL) in patients >75 years old with short duration of dual antiplatelet therapy. Before randomization, investigators recorded the planned duration of dual antiplatelet therapy (1 month for stable patients and 6 months...

TCT 2017 | REDUCE: 3 vs 12 meses de doble antiagregación con el nuevo DES Combo

TCT 2017 | REDUCE: 3 vs 12 Months of Dual Antiplatelet Therapy with the New Combo DES

Courtesy of SBHCI. This new device has, on one hand, an abluminal sirolimus coating, and on the other hand, a luminal CD34 antibody coating for EPC capturing, to potentially accelerate post-PCI reendothelization. Between 2014 and 2016, the study included 1496 patients undergoing acute coronary syndrome (ACS), receiving the new COMBO stent. These patients were randomized...

Absorb IV: la plataforma bioabsorbible con una técnica de implante perfeccionada

Absorb IV: Bioresorbable Scaffolds with an Optimized Implantation Technique

 Courtesy of the SBHCI. The Absorb IV trial randomized 2604 patients in a 1:1 ratio to receive an Absorb everolimus-eluting bioresorbable scaffold or a Xience stent. With the aim of minimizing the problems observed in previous studies, the Absorb IV protocol excluded small caliber (<2.5 mm) vessels and included mandatory aggressive pre-dilation followed by non-complacent balloon post-dilation. Patients could...

DKCRUSH-V: lo más simple no siempre es lo mejor en el tronco de la coronaria izquierda

DKCRUSH-V: What Is Simple Is Not Always Best for the Left Main Coronary Artery

Courtesy of the SBHCI. Angioplasty of true distal left main bifurcation lesions with a double-kissing (DK) crush two-stent strategy, compared with provisional stenting, results in lower rates of target lesion failure at 1 year. These findings were largely driven by lower rates of target vessel infarction and definite/probable stent thrombosis. Read also: “EXCEL-QOL Substudy: Similar Quality...

EXCEL-QOL Substudy: similar calidad de vida con cirugía y angioplastia para el tronco

EXCEL-QOL Substudy: Similar Quality of Life both with CABG and Left Main PCI

Courtesy of SBHCI. According to a new quality of life sub-study, the “EXCEL”, both coronary artery bypass graft and left main PCI are associated with significant clinical improvement in terms of angina frequency, tolerance to exertion and treatment satisfaction. At 12 and 36 months, there were no significant differences between PCI and surgery after several quality of...

CULPRIT-SHOCK Results Will Transform Guidelines and Clinical Practice

 Courtesy of the SBHCI. After treating the culprit lesion in patients with acute myocardial infarction complicated by cardiogenic shock, continuing revascularization of all other lesions worsens outcomes. This finding of the CULPRIT-SHOCK trial has changed entirely the way we treated this patient group and will surely modify guidelines. Culprit-lesion treatment with the option to perform...

DES de 2.0 mm para vasos muy pequeños: ¿Es viable?

2.0-mm DES for Very Small Vessels: Are They Viable?

The reference vessel diameter is a fundamental factor for restenosis after coronary angioplasty even with drug-eluting stents. The smallest sized stents available are 2.25 mm in diameter, but even smaller vessels can be symptomatic. This was a prospective multicenter trial of the Resolute Onyx 2.0-mm zotarolimus-eluting stent. The primary endpoint was target lesion failure. Read also: “Effects...

balon farmacologico

Excellent Outcomes for the First Sirolimus Eluting Balloon Tested on Instent Restesosis

Much has been done since studies on conventional balloon angioplasty for BMS instent restenosis showed over 40% new revascularization.  Drug eluting stents, aimed at improving this problem, have never achieved 0% restenosis, which is why technologies such as paclitaxel coated balloons have been developed, with reasonable efficacy (8% to 10% reinterventions rate for BMS restenosis and 17% to 23%...

Top