Valvular Aortic Valve articles

TCT 2020 | Eficacia del dispositivo de protección cerebral TriGUARD 3 durante el TAVI

TCT 2020 | Efficacy of Cerebral Protection Device TriGUARD 3 During TAVR

TCT 2020 | Efficacy of Cerebral Protection Device TriGUARD 3 During TAVR

Cerebral protection device TriGUARD 3, designed to cover all supra-aortic vessels during transcatheter aortic valve replacement (TAVR), is safe to use, according to the outcomes of the REFLECT II study. The technical feasibility of the device, which requires transfemoral access, does not seem to have an impact over clinical events. The primary safety endpoint was a VARC-2-defined

TCT 2020 | La Acurate Neo no alcanza la no inferioridad vs la CoreValve Evolut

TCT 2020 | Acurate Neo Does Not Meet Non-Inferiority vs. CoreValve Evolut

The self-expanding Acurate Neo (Boston Scientific) did not meet non-inferiority vs. the self-expanding CoreValve Evolut (Medtronic) in the SCOPE 2 study published in Circulation simultaneously and presented at the virtual TCT 2020. These are bad news for the Acurate Neo, that had already failed to show non-inferiority vs. the Sapien 3 in the SCOPE 1

Death, Stroke, and Hospitalization while Waiting for TAVR

The consequences of deferring transcatheter aortic valve replacement (TAVR) procedures because of the COVID 19 pandemic are piling up. Untreated severe aortic stenosis patients who had been scheduled for TAVR are seeing increased risk of all events, even mortality.  According to recent studies published in JAMA, deferring TAVR in patients with symptomatic aortic stenosis is

Post TAVR ASA Monotherapy Consolidates

This meta-analysis to be published in J Am Cardiol supports the use of aspirin monotherapy (ASA) after transcatheter aortic valve replacement (TAVR). The use of aspirin alone is associated to less bleeding without increased ischemic events such as strokes or mortality.  The combined outcomes of four studies, including the recently published POPular TAVI (cohort A),

TAVR via trans-carotidea anestesia local o general

Minimalist TAVR to the Max

Transcatheter aortic valve replacement (TAVR) is increasingly being performed under conscious sedation, which is associated with a multi-point benefit (including mortality).  This paper, recently published in JACC Intv., shows that general anesthesia is becoming obsolete, although the magnitude the benefit derived from conscious sedation appears to be lower than in previous studies. The aim of

valve_in_valve

Size Does Matter for Long Term ViV

The size of the original bioprosthetic valve impacts long term mortality, as does the type of bioprosthetic valve used in percutaneous reinterventions.  The number of patients with failed bioprosthesis is on the rise, mainly due to increased life expectancy.  Valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) has become more and more common these days and

TAVI bajo riesgo

TAVR as Anti-Inflammatory? An effect few imagined

We never saw it coming, such a pleiotropic effect: who would have though a mechanical device could have such a systemic anti-inflammatory effect? Transcatheter aortic valve replacement (TAVR) does in fact have it.  The shear stress aortic stenosis produces activates multiple inflammatory responses mediated by monocytes. This study identified the most important mechanoreceptor, involved in

TAVI: Balón expandible o autoexpandible ¿Cuál es la respuesta?

Considerations for Optimal Device Selection in TAVR

Many studies have tried to answer the question about whether there is a superior device in transcatheter aortic valve replacement (TAVR). Today, there is no evidence to support such claim, and most patients will likely find operator experience more beneficial than any device per se.   However, there are certain patients with specific characteristics that might

Trombólisis local en tromboembolismo pulmonar

TAVR After Endocarditis? Contraindication or Last Resort

Transcatheter aortic valve replacement (TAVR) can be an alternative for aortic valves with endocarditis successfully treated with antibiotics, which no longer are severe valve lesions. At one year, the risk of endocarditis relapse was low and the mortality rate was similar to that of patients without a history of infection. This aim of this study

Una nueva molécula para evitar la nefropatía por contraste

Same Contrast Dose, Different Risk of Kidney Injury, Depending on Procedure

The risk of contrast induced kidney injury is significantly lower in patients receiving transcatheter aortic valve replacement (TAVR) compared against patients getting a coronary angiography or angioplasty.  This is true even for valvular heart disease patients with higher risk profiles.  Differences in contrast-induced acute kidney injury between TAVR or coronary patients had not been previously

Dietas bajas en carbohidratos y progresión de la calcificación coronaria

Outflow Tract Calcification and the Best Valve in This Context

Moderate or severe left ventricle outflow tract calcification increases the risk of annulus rupture, residual aortic regurgitation and the need for a second valve. This recent study analyzed the performance of different contemporary prosthetic valves in patients with this particular anatomy.  Since the early days of transcatheter aortic valve replacement (TAVR) outflow tract calcification has

Top