Valvular Aortic valve articles

Centera Valvula expandible

CENTERA: Results of the New Self-Expandable Valve

CENTERA: Results of the New Self-Expandable Valve

This new device offers the advantage of a lower frame height, which reduces the chance of coronary occlusion. The delivery system is totally motorized and the valve can be repositioned. In addition, the sheath is “14 F” for all valve sizes (23, 26 and 29mm).   203 patients were included, all with severe aortic stenosis

ARTE: ¿AsEl fin de la aspirina para los pacientes anticoagulados que reciben angioplastiapirina o aspirina más clopidogrel post TAVI?

ARTE: Aspirin or Aspirin and Clopidogrel after TAVR?

Courtesy of SBHCI. This study presented at Euro PCR and simultaneously published by JACC Cardiovascular Interventions poses a question that has remained unanswered since the start of TAVR.   There is little information on the optimal antithrombotic therapy after transcatheter aortic valve replacement (TAVR). In general, patients receive between 1 and 6 months of dual

corevalve

REPRISE III: Lotus and CoreValve Compared in High-Risk or Inoperable Patients

The efficacy of transcatheter aortic valve replacement (TAVR) has been well-established. However, its limitations include suboptimal deployment and paravalvular leak. The Lotus system is a fully repositionable and retrievable device with controlled mechanical expansion. It features an adaptive seal to minimize paravalvular leak, it does not require early pacing during deployment, and, given its early

Más evidencia positiva para tratar prótesis biológicas disfuncionantes con la prótesis balón expandible

Further Evidence on Managing Dysfunctioning Bioprostheses with Balloon-Expandable Prostheses

Early experience with the valve-in-valve technique in the treatment of failed bioprosthetic surgical valves in transcatheter aortic valve replacement (TAVR) has yielded acceptable acute procedural results. This turned the technique into another therapeutic option, one that could even cause the reassessment of the age limit for the surgical implantation of a mechanical or bioprosthesis valve.

Válvula Bicúspide

Bicuspid Aortic Valve Stenosis Still Challenging for TAVR

Courtesy of Dr. Carlos Fava One of the present challenges of TAVR is bicuspid aortic valve stenosis (AS), since it presents a different distribution and structure, associated to greater and more irregular calcification. There are only small series of devices and their use is still controversial.   The study analyzed 561 patients with severe bicuspid

Reparación de la válvula tricúspide con la técnica del Mitra Clip

Tricuspid valve repair with the MitraClip technique

Current surgical and medical treatment options for severe tricuspid regurgitation are extremely limited. However, this historically forgotten valve seems to have the option of transcatheter repair, nowadays.   This observational study assessed the safety and feasibility of the MitraClip system for patients with severe chronic tricuspid regurgitation.   All patients presented severe tricuspid regurgitation and

Resonancia magnética con perfusión

Cardiovascular MR Perfusion Imaging: Good Initial Alternative in Stable Chronic Angina

In the initial management of patients with stable chronic angina, a non-invasive strategy with cardiovascular MR perfusion imaging seems to provide similar results to invasive strategies.   At one year, MACE rate (combination of all cause death, non-fatal infarction and target vessel revascularization) resulted 3.3% for MRI vs. 3.9% for fractional flow reserve (FFR) informed

Percutaneous Repair of Paravalvular Leaks After TAVR: The Challenge of Identifying Eligible Subjects

Courtesy of Dr. Carlos Fava. This study enrolled 72 patients who underwent transcatheter aortic valve replacement with an Edwards Sapiens valve, and then experienced a leak of at least moderate severity.   Fifteen of them underwent a percutaneous leak repair after identification of the leak mostly through the presence of symptoms.   Both groups were similar. Patients who

dispositivo de cierre manta en acceso femoral

MANTA Closure Device for large-bore arteriotomy closure: Is It Safe?

 Courtesy of Dr. Agustín Vecchia.  The number of transcatheter aortic valve replacements (TAVR) and the placement of aortic endoprosthesis and ventricular assist devices, among others, have grown exponentially worldwide in the last few years. In a short time, many of these procedures will surely become the new standard of care. Logically, this growth comes hand in hand

indices de fragilidad en tavi

TAVI Frailty Indices: We Should Start Using Them

Courtesy of Dr. Carlos Fava. Frailty should be taken into account when deciding transcatheter aortic valve implantation (TAVI). Even though several scales of frailty are available, they are yet to be tested in this group, with this strategy.   The study analyzed 101 patients, frailty was assessed clinically according to the following tests: Katz index

Marcapaseo con la guía 0.035” TAVI

Pacing with a 0.035” Guidewire, an Old Technique Coming Back to Simplify TAVR

This study seeks to prove the safety and efficacy of rapid left ventricular pacing through a 0.035” guidewire during aortic valvuloplasty and transcatheter aortic valve replacement (TAVR).   Right ventricular temporary pacing placed through venous access during aortic valvuloplasty or during TAVR is time-consuming and, above all, associated with cardiac perforation and tamponade.   Since

Top